Simulation of Electrical Field Around Track
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F13%3A86086079" target="_blank" >RIV/61989100:27240/13:86086079 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simulation of Electrical Field Around Track
Popis výsledku v původním jazyce
One of the negative effects of railroad tracks that are powered by direct current railway electrification system are stray voltages. Stray voltages cause electrochemical corrosion, which causes damage of cable storage system around the track. For simulate this situation was created a model in Matlab Simulink program. It was modeled single-track with two consumptions and with two driving vehicles in powered section. The simulation model is created by using lines with a nominal length, which is at the ends supplied by power supply voltage of 3.3kV. These sources represent the individual transformers that regulate voltage level in the network. In this model, the two locomotives are on one track. The track is 3 km long. Ground layers were inserted in the simulation model into subsystems, which improved the orientation of the entire model. Individual results of the subsystem are shown in the graphs. Sizes earth currents are mainly influenced by resistance and capacity of earth structure of one layer.
Název v anglickém jazyce
Simulation of Electrical Field Around Track
Popis výsledku anglicky
One of the negative effects of railroad tracks that are powered by direct current railway electrification system are stray voltages. Stray voltages cause electrochemical corrosion, which causes damage of cable storage system around the track. For simulate this situation was created a model in Matlab Simulink program. It was modeled single-track with two consumptions and with two driving vehicles in powered section. The simulation model is created by using lines with a nominal length, which is at the ends supplied by power supply voltage of 3.3kV. These sources represent the individual transformers that regulate voltage level in the network. In this model, the two locomotives are on one track. The track is 3 km long. Ground layers were inserted in the simulation model into subsystems, which improved the orientation of the entire model. Individual results of the subsystem are shown in the graphs. Sizes earth currents are mainly influenced by resistance and capacity of earth structure of one layer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Elektroenergetika 2013 : proceedings of the 7th International Scientific Symposium on Electrical Power Engineering : Stará Lesná, High Tatras, September 18-20, 2013
ISBN
978-80-553-1442-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
117-120
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
18. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000333395100027