Orthogonal matching pursuit based classifier for premature ventricular contraction detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86096061" target="_blank" >RIV/61989100:27240/14:86096061 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27740/14:86096061
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-01854-6_21" target="_blank" >http://dx.doi.org/10.1007/978-3-319-01854-6_21</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-01854-6_21" target="_blank" >10.1007/978-3-319-01854-6_21</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Orthogonal matching pursuit based classifier for premature ventricular contraction detection
Popis výsledku v původním jazyce
Premature Ventricular Contractions (PVCs) are a common topic of discussion among cardiologists as this type of heart arrhythmia is very frequent among the general population, often endangering people's health. In this paper, a software system is proposedthat differentiates PVCs from normal, healthy heartbeats collected in the MIT-BIH Arrhythmia Database. During classification, training data were recorded from subjects different than those from which testing data were measured, making the classifiers attempt to recognize patterns they were not trained for. A modification of the Orthogonal Matching Pursuit (OMP) based classifier is described and used for comparison with other, wellestablished classifiers. The absolute accuracy of the described algorithmis 87.58%. More elaboration on the results based on cross-reference is also given. (C) Springer International Publishing Switzerland 2014.
Název v anglickém jazyce
Orthogonal matching pursuit based classifier for premature ventricular contraction detection
Popis výsledku anglicky
Premature Ventricular Contractions (PVCs) are a common topic of discussion among cardiologists as this type of heart arrhythmia is very frequent among the general population, often endangering people's health. In this paper, a software system is proposedthat differentiates PVCs from normal, healthy heartbeats collected in the MIT-BIH Arrhythmia Database. During classification, training data were recorded from subjects different than those from which testing data were measured, making the classifiers attempt to recognize patterns they were not trained for. A modification of the Orthogonal Matching Pursuit (OMP) based classifier is described and used for comparison with other, wellestablished classifiers. The absolute accuracy of the described algorithmis 87.58%. More elaboration on the results based on cross-reference is also given. (C) Springer International Publishing Switzerland 2014.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE.2.3.20.0073" target="_blank" >EE.2.3.20.0073: Bio-inspirované metody: věda, vzdělávání a transfer znalostí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advances in Intelligent Systems and Computing. Volume 239
ISBN
978-3-319-01853-9
ISSN
2194-5357
e-ISSN
—
Počet stran výsledku
10
Strana od-do
201-210
Název nakladatele
Springer
Místo vydání
New York
Místo konání akce
Salamanca
Datum konání akce
11. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—