Illuminance evaluation in automatically dimmed interior lighting systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86098277" target="_blank" >RIV/61989100:27240/16:86098277 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7745513/?reload=true" target="_blank" >http://ieeexplore.ieee.org/document/7745513/?reload=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/LUMENV.2016.7745513" target="_blank" >10.1109/LUMENV.2016.7745513</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Illuminance evaluation in automatically dimmed interior lighting systems
Popis výsledku v původním jazyce
To verify a quality of dimmed lighting systems with illuminance regulation to constant level it was necessary to develop an automatic measuring system. This system works as a long-term measurement of illuminance of interior workplace (10 illuminance at the same time) together with the daylight measurement. This system measures horizontal illuminance at the workplace as it is required by norms. However, the sensors used in dimmed interior lighting systems are generally placed on the ceiling and that is why the automatic system could not work well and final measured illuminance at the workplace could be different from the set request (norm) if there is a dynamic daylight in the room.
Název v anglickém jazyce
Illuminance evaluation in automatically dimmed interior lighting systems
Popis výsledku anglicky
To verify a quality of dimmed lighting systems with illuminance regulation to constant level it was necessary to develop an automatic measuring system. This system works as a long-term measurement of illuminance of interior workplace (10 illuminance at the same time) together with the daylight measurement. This system measures horizontal illuminance at the workplace as it is required by norms. However, the sensors used in dimmed interior lighting systems are generally placed on the ceiling and that is why the automatic system could not work well and final measured illuminance at the workplace could be different from the set request (norm) if there is a dynamic daylight in the room.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 2016 IEEE Lighting Conference of the Visegrad Countries, Lumen V4 2016, 13-16 September, Karpacz, Poland
ISBN
978-1-5090-3305-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Institute of Electrical and Electronics Engineers
Místo vydání
New York
Místo konání akce
Karpacz
Datum konání akce
13. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—