Drop Evaporation Test for stress corrosion cracking study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F03%3A00008728" target="_blank" >RIV/61989100:27360/03:00008728 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Drop Evaporation Test for stress corrosion cracking study
Popis výsledku v původním jazyce
The drop evaporation test (DET) was developed for study of stainless steels resistance to stress corrosion cracking (SCC) at elevated temperatures 120 - 300 °C under constant external load and dropping of diluted sodium chloride water solution. The resistance to SCC is determined according to time to fracture - tensile stress relations and conventional threshold stress. The alloy (steel) NiCrWTiAl 35-15-5 after thermal hardening and long-time service exposition was tested under DET conditions and corrosion cracks were evaluated by metallography and fractography. The microscopic pits and corrosion crack tips coordinates measurement by the travelling microscope method allowed to determine their lengths and rates as function of time and stress intensity factor. These calculated rates were higher when cracks leaving the pits. The resistance to intergranular corrosion was compared by DL-EPR (double loop electrochemical potenciokinetic reactivation) method.
Název v anglickém jazyce
Drop Evaporation Test for stress corrosion cracking study
Popis výsledku anglicky
The drop evaporation test (DET) was developed for study of stainless steels resistance to stress corrosion cracking (SCC) at elevated temperatures 120 - 300 °C under constant external load and dropping of diluted sodium chloride water solution. The resistance to SCC is determined according to time to fracture - tensile stress relations and conventional threshold stress. The alloy (steel) NiCrWTiAl 35-15-5 after thermal hardening and long-time service exposition was tested under DET conditions and corrosion cracks were evaluated by metallography and fractography. The microscopic pits and corrosion crack tips coordinates measurement by the travelling microscope method allowed to determine their lengths and rates as function of time and stress intensity factor. These calculated rates were higher when cracks leaving the pits. The resistance to intergranular corrosion was compared by DL-EPR (double loop electrochemical potenciokinetic reactivation) method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F02%2F1569" target="_blank" >GA106/02/1569: Studium degradace korozivzdorných materiálů v podmínkách vysolování za zvýšených teplot</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The Europ. Cor. Congress EUROCORR 2003
ISBN
80-81-365
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
25-33
Název nakladatele
Eurocorr
Místo vydání
Budapest
Místo konání akce
Terchova
Datum konání akce
28. 10. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—