Determination of neopterin, kynurenine, tryptophan and creatinine in human serum by high throuput HPLC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F11%3A10223934" target="_blank" >RIV/61989592:15110/11:10223934 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/11:10100325 RIV/00216208:11160/11:10100325 RIV/00179906:_____/11:10100325
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of neopterin, kynurenine, tryptophan and creatinine in human serum by high throuput HPLC
Popis výsledku v původním jazyce
A new HPLC method for simultaneous determination of neopterin, creatinine, kynurenine and tryptophan in human serum was developed and validated. Monolithic stationary phase's technology (two monolithic columns RP-18e were connected with guard monolithiccartridge 4.6 mm x 50 mm + 3.0 mm x 100 mm and 4.6 x 10 mm) and special auto sampler for micro titration plates (samples are storage in dark cooled place protected against evaporation) were combined with easy sample preparation step. As mobile phase 15 mmol/L phosphate buffer at pH 4.50 was used. Neopterin and tryptophan were detected using fluorescent detection and kynurenine and creatinine were detected by diode-array detection. This method may be suitable for large sequences of samples in clinical research and routine practice. (C) 2011 Elsevier B.V. All rights reserved.
Název v anglickém jazyce
Determination of neopterin, kynurenine, tryptophan and creatinine in human serum by high throuput HPLC
Popis výsledku anglicky
A new HPLC method for simultaneous determination of neopterin, creatinine, kynurenine and tryptophan in human serum was developed and validated. Monolithic stationary phase's technology (two monolithic columns RP-18e were connected with guard monolithiccartridge 4.6 mm x 50 mm + 3.0 mm x 100 mm and 4.6 x 10 mm) and special auto sampler for micro titration plates (samples are storage in dark cooled place protected against evaporation) were combined with easy sample preparation step. As mobile phase 15 mmol/L phosphate buffer at pH 4.50 was used. Neopterin and tryptophan were detected using fluorescent detection and kynurenine and creatinine were detected by diode-array detection. This method may be suitable for large sequences of samples in clinical research and routine practice. (C) 2011 Elsevier B.V. All rights reserved.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
TALANTA
ISSN
0039-9140
e-ISSN
—
Svazek periodika
85
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1466-1471