Magnification of digital hip radiographs differs between clinical workplaces
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F17%3A73585623" target="_blank" >RIV/61989592:15110/17:73585623 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/17:10366247 RIV/68407700:21220/17:00319401 RIV/00064203:_____/17:10366247 RIV/00216208:11110/17:10366247
Výsledek na webu
<a href="http://dx.doi.org/10.1371/journal.pone.0188743" target="_blank" >http://dx.doi.org/10.1371/journal.pone.0188743</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0188743" target="_blank" >10.1371/journal.pone.0188743</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Magnification of digital hip radiographs differs between clinical workplaces
Popis výsledku v původním jazyce
Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.
Název v anglickém jazyce
Magnification of digital hip radiographs differs between clinical workplaces
Popis výsledku anglicky
Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-31269A" target="_blank" >NV15-31269A: Studium nových materiálů pro artikulační povrchy kloubních náhrad</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS One
ISSN
1932-6203
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000416841900115
EID výsledku v databázi Scopus
2-s2.0-85036629768