Assessment of CE for the identification of microorganisms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F09%3A00010411" target="_blank" >RIV/61989592:15310/09:00010411 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of CE for the identification of microorganisms
Popis výsledku v původním jazyce
The assessment of capillary electrophoresis for separation and identification of microorganisms is described in this article. The work brings a comparison of the application of uncoated capillaries modified with poly(ethylene oxide) and coated capillaries for the separation of model microorganisms Saccharomyces cerevisiae and Escherichia coli with Tris-borate-EDTA and Tris-citrate-fructose as electrolytes. The best separation was achieved in the coated capillary using 1 mM Tris-citrate-fructose buffer,pH 6.9. A simple identification based on the migration time and UV spectrum was found unsatisfactory and thus a method based on a post-separation cultivation and sequential analysis was developed. Off-line combination with mass spectrometric analysis with the use of desorption electrospray was shown to be an interesting alternative in a study of microorganisms. Mass spectra allowed distinguishing among analyzed cells.
Název v anglickém jazyce
Assessment of CE for the identification of microorganisms
Popis výsledku anglicky
The assessment of capillary electrophoresis for separation and identification of microorganisms is described in this article. The work brings a comparison of the application of uncoated capillaries modified with poly(ethylene oxide) and coated capillaries for the separation of model microorganisms Saccharomyces cerevisiae and Escherichia coli with Tris-borate-EDTA and Tris-citrate-fructose as electrolytes. The best separation was achieved in the coated capillary using 1 mM Tris-citrate-fructose buffer,pH 6.9. A simple identification based on the migration time and UV spectrum was found unsatisfactory and thus a method based on a post-separation cultivation and sequential analysis was developed. Off-line combination with mass spectrometric analysis with the use of desorption electrospray was shown to be an interesting alternative in a study of microorganisms. Mass spectra allowed distinguishing among analyzed cells.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—