Determination of selected biogenic amines in red wines by automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142148" target="_blank" >RIV/61989592:15310/12:33142148 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jchromb.2012.07.018" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2012.07.018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchromb.2012.07.018" target="_blank" >10.1016/j.jchromb.2012.07.018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of selected biogenic amines in red wines by automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis
Popis výsledku v původním jazyce
A screening analytical method based on an automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis (cITP-CZE) in hydrodynamically closed separation system, equipped with photometric detection at 280 nm. was developed fora routine determination of the selected biogenic amines, namely histamine, 2-phenylethylamine and tyramine, in red wines. The evaluated limits of detection (LODs) were 0.35 mg L-1 for histamine, 0.33 mg L-1 for 2-phenylethylamine and 0.37 mg L-1 for tyramine. The repeatability of the migration time and peak area for histamine were 1.1% and 2.6%, respectively, for 2-phenylethylamine 0.7% and 2.0%, respectively, and for tyramine 0.8% and 2.1%. respectively. The method recoveries were 92.1% for histamine,96.4% for 2-phenylethylamine and 95.5% for tyramine. The developed automated cITP-CZE-UV method was applied for the determination of histamine, 2-phenylethylamine and tyramine in seven red wine samples originating from Czech Republic.
Název v anglickém jazyce
Determination of selected biogenic amines in red wines by automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis
Popis výsledku anglicky
A screening analytical method based on an automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis (cITP-CZE) in hydrodynamically closed separation system, equipped with photometric detection at 280 nm. was developed fora routine determination of the selected biogenic amines, namely histamine, 2-phenylethylamine and tyramine, in red wines. The evaluated limits of detection (LODs) were 0.35 mg L-1 for histamine, 0.33 mg L-1 for 2-phenylethylamine and 0.37 mg L-1 for tyramine. The repeatability of the migration time and peak area for histamine were 1.1% and 2.6%, respectively, for 2-phenylethylamine 0.7% and 2.0%, respectively, and for tyramine 0.8% and 2.1%. respectively. The method recoveries were 92.1% for histamine,96.4% for 2-phenylethylamine and 95.5% for tyramine. The developed automated cITP-CZE-UV method was applied for the determination of histamine, 2-phenylethylamine and tyramine in seven red wine samples originating from Czech Republic.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0058" target="_blank" >ED2.1.00/03.0058: Regionální centrum pokročilých technologií a materiálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences
ISSN
1570-0232
e-ISSN
—
Svazek periodika
904
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
135-139
Kód UT WoS článku
000308734400018
EID výsledku v databázi Scopus
—