Analysis of cytokinin nucleotides by capillary zone electrophoresis with diode array and mass spectrometric detection in a recombinant enzyme in vitro reaction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142716" target="_blank" >RIV/61989592:15310/12:33142716 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389030:_____/12:00385991 RIV/61989592:15110/12:33142716
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0003267012012792" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0003267012012792</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2012.08.049" target="_blank" >10.1016/j.aca.2012.08.049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of cytokinin nucleotides by capillary zone electrophoresis with diode array and mass spectrometric detection in a recombinant enzyme in vitro reaction
Popis výsledku v původním jazyce
A capillary zone electrophoresis (CZE) method for separation of adenosine and N-6-isopentenyladenosine (cytokinin) nucleotides was developed, optimized and validated. Aqueous solutions of several amino acids were evaluated as the background electrolyte constituents. Separation of six nucleotides in less than 20 min with high theoretical plate number (up to 400 000 for isopentenyladenosine triphosphate) was achieved using a 100 mM sarcosine/ammonia buffer at pH 10.0. The detection limits of the CZE-UV method are in the low micromolar range (0.69-1.27 mu mol L-1). Good repeatability of migration times (within 1.3%), peak areas (within 1.8%) and linearity (R-2 }0.999) was achieved over the concentration range 5-1000 mu mol L-1. The method was used to assay the activity of the recombinant Arabidopsis thaliana isopentenyltransferase 1 (AtIPT1). Baseline separation of isopentenylated nucleotides by CE-ESI-MS using a volatile buffer (30 mM ammonium formate; pH 10.0) was accomplished. The iden
Název v anglickém jazyce
Analysis of cytokinin nucleotides by capillary zone electrophoresis with diode array and mass spectrometric detection in a recombinant enzyme in vitro reaction
Popis výsledku anglicky
A capillary zone electrophoresis (CZE) method for separation of adenosine and N-6-isopentenyladenosine (cytokinin) nucleotides was developed, optimized and validated. Aqueous solutions of several amino acids were evaluated as the background electrolyte constituents. Separation of six nucleotides in less than 20 min with high theoretical plate number (up to 400 000 for isopentenyladenosine triphosphate) was achieved using a 100 mM sarcosine/ammonia buffer at pH 10.0. The detection limits of the CZE-UV method are in the low micromolar range (0.69-1.27 mu mol L-1). Good repeatability of migration times (within 1.3%), peak areas (within 1.8%) and linearity (R-2 }0.999) was achieved over the concentration range 5-1000 mu mol L-1. The method was used to assay the activity of the recombinant Arabidopsis thaliana isopentenyltransferase 1 (AtIPT1). Baseline separation of isopentenylated nucleotides by CE-ESI-MS using a volatile buffer (30 mM ammonium formate; pH 10.0) was accomplished. The iden
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
751
Číslo periodika v rámci svazku
NOV
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
176-181
Kód UT WoS článku
000311013100021
EID výsledku v databázi Scopus
—