Enantiomeric separation of R,S-tolterodine and R,S-methoxytolterodine with negatively charged cyclodextrins by capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F13%3A33147348" target="_blank" >RIV/61989592:15310/13:33147348 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.201200530" target="_blank" >http://dx.doi.org/10.1002/jssc.201200530</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201200530" target="_blank" >10.1002/jssc.201200530</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enantiomeric separation of R,S-tolterodine and R,S-methoxytolterodine with negatively charged cyclodextrins by capillary electrophoresis
Popis výsledku v původním jazyce
The methods for separation of R,S-tolterodine and R,S-methoxytolterodine enantiomers using sulfated -, -CD and phosphated--CD by CE in acidic BGE based on Tris/phosphate pH 2.5 buffer were developed. Sulfated - and -CD allow anodic detection while phosphated--CD allows only cathodic detection of the separated enantiomers. The influence of chiral selector (CS)'s concentration as well as the influence of composition and concentration of BGE on resolutions were studied. Reversal migration order of tolterodine and methoxytolterodine enantiomers was observed, when sulfated-- and sulfated--CD were used. The developed methods with all three studied CSs, were validated and compared. All proposed methods enable determination of 0.2% of S-tolterodine as an optical impurity in pills, however the method with phosphated--CD provided lower detection limit, better repeatability of peak areas and migration times, and also lower consumption of CS. Developed method employing phosphated--CD that was appl
Název v anglickém jazyce
Enantiomeric separation of R,S-tolterodine and R,S-methoxytolterodine with negatively charged cyclodextrins by capillary electrophoresis
Popis výsledku anglicky
The methods for separation of R,S-tolterodine and R,S-methoxytolterodine enantiomers using sulfated -, -CD and phosphated--CD by CE in acidic BGE based on Tris/phosphate pH 2.5 buffer were developed. Sulfated - and -CD allow anodic detection while phosphated--CD allows only cathodic detection of the separated enantiomers. The influence of chiral selector (CS)'s concentration as well as the influence of composition and concentration of BGE on resolutions were studied. Reversal migration order of tolterodine and methoxytolterodine enantiomers was observed, when sulfated-- and sulfated--CD were used. The developed methods with all three studied CSs, were validated and compared. All proposed methods enable determination of 0.2% of S-tolterodine as an optical impurity in pills, however the method with phosphated--CD provided lower detection limit, better repeatability of peak areas and migration times, and also lower consumption of CS. Developed method employing phosphated--CD that was appl
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
9-10
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
1561-1567
Kód UT WoS článku
000319866800009
EID výsledku v databázi Scopus
—