Study of bulk damage of high dose gamma irradiated p-type silicon diodes with various resistivities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F24%3A73627626" target="_blank" >RIV/61989592:15310/24:73627626 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/19/02/C02039/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/19/02/C02039/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/19/02/C02039" target="_blank" >10.1088/1748-0221/19/02/C02039</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of bulk damage of high dose gamma irradiated p-type silicon diodes with various resistivities
Popis výsledku v původním jazyce
The bulk damage of p-type silicon detectors caused by high doses of gamma irradiation has been studied. The study was carried out on three types of n(+)-in-p silicon diodes with comparable geometries but different initial resistivities. This allowed to determine how different initial parameters of studied samples influence radiation-induced changes in the measured characteristics. The diodes were irradiated by a Cobalt-60 gamma source to total ionizing doses ranging from 0.50 up to 8.28 MGy, and annealed for 80 minutes at 60 degrees C. The Geant4 toolkit for simulation of the passage of particles through matter was used to simulate the deposited energy homogeneity, to verify the equal distribution of total deposited energies through all the layers of irradiated samples, and to calculate the secondary electron spectra in the irradiation box. The main goal of the study was to characterize the gamma-radiation induced displacement damage by measuring current-voltage characteristics (IV), and the evolution of the full depletion voltage (V-FD) with the total ionizing dose, by measuring capacitance-voltage characteristics (CV). It has been observed that the bulk leakage current increases linearly with total ionizing dose, and the damage coefficient depends on the initial resistivity of the silicon diode. The effective doping concentration and therefore V-FD significantly decreases with increasing total ionizing dose, before starting to increase again at a specific dose. We assume that this decrease is caused by the effect of acceptor removal. Another noteworthy observation of this study is that the IV and CV measurements of the gamma irradiated diodes do not reveal any annealing effect.
Název v anglickém jazyce
Study of bulk damage of high dose gamma irradiated p-type silicon diodes with various resistivities
Popis výsledku anglicky
The bulk damage of p-type silicon detectors caused by high doses of gamma irradiation has been studied. The study was carried out on three types of n(+)-in-p silicon diodes with comparable geometries but different initial resistivities. This allowed to determine how different initial parameters of studied samples influence radiation-induced changes in the measured characteristics. The diodes were irradiated by a Cobalt-60 gamma source to total ionizing doses ranging from 0.50 up to 8.28 MGy, and annealed for 80 minutes at 60 degrees C. The Geant4 toolkit for simulation of the passage of particles through matter was used to simulate the deposited energy homogeneity, to verify the equal distribution of total deposited energies through all the layers of irradiated samples, and to calculate the secondary electron spectra in the irradiation box. The main goal of the study was to characterize the gamma-radiation induced displacement damage by measuring current-voltage characteristics (IV), and the evolution of the full depletion voltage (V-FD) with the total ionizing dose, by measuring capacitance-voltage characteristics (CV). It has been observed that the bulk leakage current increases linearly with total ionizing dose, and the damage coefficient depends on the initial resistivity of the silicon diode. The effective doping concentration and therefore V-FD significantly decreases with increasing total ionizing dose, before starting to increase again at a specific dose. We assume that this decrease is caused by the effect of acceptor removal. Another noteworthy observation of this study is that the IV and CV measurements of the gamma irradiated diodes do not reveal any annealing effect.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Instrumentation
ISBN
—
ISSN
1748-0221
e-ISSN
—
Počet stran výsledku
10
Strana od-do
"C02039-1"-"C02039-10"
Název nakladatele
Institute of Physics
Místo vydání
Bristol
Místo konání akce
Oslo
Datum konání akce
25. 6. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001186307200007