Measurements of Flat-Plate Milk Coolers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F14%3A00228539" target="_blank" >RIV/62156489:43210/14:00228539 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.11118/actaun201462051057" target="_blank" >http://dx.doi.org/10.11118/actaun201462051057</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.11118/actaun201462051057" target="_blank" >10.11118/actaun201462051057</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurements of Flat-Plate Milk Coolers
Popis výsledku v původním jazyce
Measuring in laboratory conditions was performed with the aim to collect a sufficient quantity of measured data for the qualified application of flat-plate coolers in measuring under real operating conditions. The operating measurement was carried out onthe basis of the results of laboratory measurements. The objective was to determine to what extent the use of flat-plate coolers under specific conditions results in cost reduction and improved milk cooling process. The measurement was performed in several cycles. The first measurement took place in the existing system without the use of the flat-plate cooler. The volume of drawn milk was monitored throughout the milking process along with its temperature, temperature in the tank and electricity consumption of the cooling system. At the second stage, the flat-plate cooler was introduced into the cooling process, which was followed by monitoring the milk and cooling water volume, their temperature, temperature in the tank and electricit
Název v anglickém jazyce
Measurements of Flat-Plate Milk Coolers
Popis výsledku anglicky
Measuring in laboratory conditions was performed with the aim to collect a sufficient quantity of measured data for the qualified application of flat-plate coolers in measuring under real operating conditions. The operating measurement was carried out onthe basis of the results of laboratory measurements. The objective was to determine to what extent the use of flat-plate coolers under specific conditions results in cost reduction and improved milk cooling process. The measurement was performed in several cycles. The first measurement took place in the existing system without the use of the flat-plate cooler. The volume of drawn milk was monitored throughout the milking process along with its temperature, temperature in the tank and electricity consumption of the cooling system. At the second stage, the flat-plate cooler was introduced into the cooling process, which was followed by monitoring the milk and cooling water volume, their temperature, temperature in the tank and electricit
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
ISSN
1211-8516
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
1057-1064
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—