Optimizing operating parameters for flat-plate milk coolers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F14%3A00229360" target="_blank" >RIV/62156489:43210/14:00229360 - isvavai.cz</a>
Výsledek na webu
<a href="http://mnet.mendelu.cz/mendelnet2014/index.php?page=82&lang=eng" target="_blank" >http://mnet.mendelu.cz/mendelnet2014/index.php?page=82&lang=eng</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing operating parameters for flat-plate milk coolers
Popis výsledku v původním jazyce
Measuring in laboratory conditions was performed with the aim to collect a sufficient quantity of measured data for the qualified application of flat-plate coolers in measuring under real operating conditions. The cooling water tank was filled with tap water; the second tank was filled with water at a temperature equivalent to freshly milked milk. At the same time, pumps were activated that delivered the liquids into the flat-plate cooler where heat energy was exchanged between the two media. Two containers for receiving the run-out liquid were placed on the outputs from the cooler; here, temperature was measured with electronic thermometer and weight was measured with calibrated scales. Flow rate was regulated both on the side of the cooling fluid andon the side of the cooled liquid by means of a throttle valve. The measurements of regulated flow-rates were repeated five times and the final values were calculated using arithmetic mean and optimum flow ratio calculated by program MATL
Název v anglickém jazyce
Optimizing operating parameters for flat-plate milk coolers
Popis výsledku anglicky
Measuring in laboratory conditions was performed with the aim to collect a sufficient quantity of measured data for the qualified application of flat-plate coolers in measuring under real operating conditions. The cooling water tank was filled with tap water; the second tank was filled with water at a temperature equivalent to freshly milked milk. At the same time, pumps were activated that delivered the liquids into the flat-plate cooler where heat energy was exchanged between the two media. Two containers for receiving the run-out liquid were placed on the outputs from the cooler; here, temperature was measured with electronic thermometer and weight was measured with calibrated scales. Flow rate was regulated both on the side of the cooling fluid andon the side of the cooled liquid by means of a throttle valve. The measurements of regulated flow-rates were repeated five times and the final values were calculated using arithmetic mean and optimum flow ratio calculated by program MATL
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MendelNet 2014 - Proceedings of International PhD Students Conference
ISBN
978-80-7509-174-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
552-556
Název nakladatele
Mendel University in Brno
Místo vydání
Brno, Czech Republic
Místo konání akce
Brno, Czech Republic
Datum konání akce
19. 11. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—