Application of FT NIR spectroscopy in the determination of basic physical and chemical parameters of sausages
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F10%3A00002847" target="_blank" >RIV/62157124:16270/10:00002847 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of FT NIR spectroscopy in the determination of basic physical and chemical parameters of sausages
Popis výsledku v původním jazyce
The objectives of this study were to develop calibration models for determination of water activity and the content of fat, dry matter, salt, non collagen muscle protein and pH in dry cooked sausages. Samples (n = 42) were scanned in FT-NIR Analyzer andsimultaneously analyzed by standard methods. The spectra were measured in the reflectance mode with a compressive cell between 10 000 and 4 000 cm-1, averaging 100 scans. Calibration models were developed using the partial least squares (PLS) method. These calibration models were checked later by cross-validation. The following statistical values were obtained: R (correlation coefficient) = 0.997 and SEC (standard error of calibration) = 0.002 for water activity, R = 0.966 and SEC = 0.023 for pH, R = 0.995 and SEC = 0.970 for dry matter content, R = 0.995 and SEC = 0.045 for salt content, R = 0.965 and SEC = 0.652 for non collagen muscle protein, R = 0.996 and SEC = 0.559 for fat content. The results of the study showed that FT-NIR is a
Název v anglickém jazyce
Application of FT NIR spectroscopy in the determination of basic physical and chemical parameters of sausages
Popis výsledku anglicky
The objectives of this study were to develop calibration models for determination of water activity and the content of fat, dry matter, salt, non collagen muscle protein and pH in dry cooked sausages. Samples (n = 42) were scanned in FT-NIR Analyzer andsimultaneously analyzed by standard methods. The spectra were measured in the reflectance mode with a compressive cell between 10 000 and 4 000 cm-1, averaging 100 scans. Calibration models were developed using the partial least squares (PLS) method. These calibration models were checked later by cross-validation. The following statistical values were obtained: R (correlation coefficient) = 0.997 and SEC (standard error of calibration) = 0.002 for water activity, R = 0.966 and SEC = 0.023 for pH, R = 0.995 and SEC = 0.970 for dry matter content, R = 0.995 and SEC = 0.045 for salt content, R = 0.965 and SEC = 0.652 for non collagen muscle protein, R = 0.996 and SEC = 0.559 for fat content. The results of the study showed that FT-NIR is a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Svazek periodika
79
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000282195800015
EID výsledku v databázi Scopus
—