Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F63108089%3A_____%2F09%3A%230000002" target="_blank" >RIV/63108089:_____/09:#0000002 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)
Popis výsledku v původním jazyce
The work deals with an evaluation of organ doses and effective doses from two verification techniques in image-guided radiotherapy (IGRT): from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections. Both verification techniques help to improve patient setup procedure. On the other hand, using these verification techniques also causes delivering higher doses to healthy organs. Measurements of organ doses were performed at two hospitals using two different imaging systems: On-Board Imager (OBI) and X-ray Volume Imaging (XVI). Organ doses were evaluated in 27 organs for pelvis and head treatment. Measurements of organ doses were performed in an male anthropomorphic Rando phantom by means of thermoluminescent dosimeters (TLDs).Effective doses were calculated from measured organ doses using two ICRP recommendations (ICRP 60 and ICRP 103).
Název v anglickém jazyce
Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)
Popis výsledku anglicky
The work deals with an evaluation of organ doses and effective doses from two verification techniques in image-guided radiotherapy (IGRT): from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections. Both verification techniques help to improve patient setup procedure. On the other hand, using these verification techniques also causes delivering higher doses to healthy organs. Measurements of organ doses were performed at two hospitals using two different imaging systems: On-Board Imager (OBI) and X-ray Volume Imaging (XVI). Organ doses were evaluated in 27 organs for pelvis and head treatment. Measurements of organ doses were performed in an male anthropomorphic Rando phantom by means of thermoluminescent dosimeters (TLDs).Effective doses were calculated from measured organ doses using two ICRP recommendations (ICRP 60 and ICRP 103).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/JC_4%2F2009" target="_blank" >JC_4/2009: Stanovování a ověřování dávek při pokročilých radioterapeutických metodách (IMRT, IGRT).</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings - World Congress on Medical Physics and Biomedical Engineering
ISBN
978-3-642-03901-0
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Springer
Místo vydání
Heidelberg
Místo konání akce
Mnichov
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—