Organ and effective doses from verification techniques in Image-Guided Radiotherapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F11%3A00191466" target="_blank" >RIV/68407700:21340/11:00191466 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/86652052:_____/11:#0000032
Výsledek na webu
<a href="http://rpd.oxfordjournals.org/cgi/reprint/ncr335?ijkey=ZCWsw7OMD7Z5ruS&keytype=ref" target="_blank" >http://rpd.oxfordjournals.org/cgi/reprint/ncr335?ijkey=ZCWsw7OMD7Z5ruS&keytype=ref</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncr335" target="_blank" >10.1093/rpd/ncr335</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Organ and effective doses from verification techniques in Image-Guided Radiotherapy
Popis výsledku v původním jazyce
The purpose of this work was to evaluate organ doses and effective doses from three verification techniques in Image-Guided Radiotherapy: from kilovoltage (kV) cone beam CT (CBCT) scans, from two orthogonal kV images, and from two orthogonal megavoltage(MV) images for two different treatment sites: pelvis and head and neck (H&N). For comparison reasons, organ doses and effective doses from prostate and H&N radiotherapy were also evaluated. Measurements of organ doses were performed in a male anthropomorphic Rando phantom by means of thermoluminescent dosemeters (TLDs) MCP-N. In our investigation, measured organ doses from one CBCT scan, from two MV images, and from two kV images of pelvis represent typically 1 to 6 %, 1 to 10 %, and 0.05 to 1 %, respectively, of organ doses resulting from one fraction of prostate radiotherapy. The maximum effective doses from one CBCT scan, two kV images and two MV images of pelvis are 5.6 mSv, 0.8 mSv and 11.9 mSv, respectively.
Název v anglickém jazyce
Organ and effective doses from verification techniques in Image-Guided Radiotherapy
Popis výsledku anglicky
The purpose of this work was to evaluate organ doses and effective doses from three verification techniques in Image-Guided Radiotherapy: from kilovoltage (kV) cone beam CT (CBCT) scans, from two orthogonal kV images, and from two orthogonal megavoltage(MV) images for two different treatment sites: pelvis and head and neck (H&N). For comparison reasons, organ doses and effective doses from prostate and H&N radiotherapy were also evaluated. Measurements of organ doses were performed in a male anthropomorphic Rando phantom by means of thermoluminescent dosemeters (TLDs) MCP-N. In our investigation, measured organ doses from one CBCT scan, from two MV images, and from two kV images of pelvis represent typically 1 to 6 %, 1 to 10 %, and 0.05 to 1 %, respectively, of organ doses resulting from one fraction of prostate radiotherapy. The maximum effective doses from one CBCT scan, two kV images and two MV images of pelvis are 5.6 mSv, 0.8 mSv and 11.9 mSv, respectively.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/JC_4%2F2009" target="_blank" >JC_4/2009: Stanovování a ověřování dávek při pokročilých radioterapeutických metodách (IMRT, IGRT).</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
147
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
277-280