Analýza etylglukuronidu v lidském séru kapilární elektroforézou se self-stackingem vzorku a nepřímou detekcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F05%3A00021363" target="_blank" >RIV/68081715:_____/05:00021363 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of ethyl glucuronide in human serum by capillary electrophoresis with sample self-stacking and indirect detection
Popis výsledku v původním jazyce
Ethyl glucuronide (EtG), a metabolite of ethanol, is a marker of recent alcohol consumption. The capillary zone electrophoresis analysis of EtG in model mixtures and human serum is reported using uncoated and coated fused-silica capillaries together withacidic buffers in the pH range between 3.2 and 4.4 and indirect detection. In these approaches, separation of EtG from anionic serum components of high and low concentration is based upon transient isotachophoretic stacking. A buffer composed of 10 mM nicotinic acid and epsilon-aminocaproic acid (pH 4.3) is demonstrated to provide a detection limit for EtG in serum of 0.1 microg/ml, a value that is relevant for clinical and forensic purposes.
Název v anglickém jazyce
Analysis of ethyl glucuronide in human serum by capillary electrophoresis with sample self-stacking and indirect detection
Popis výsledku anglicky
Ethyl glucuronide (EtG), a metabolite of ethanol, is a marker of recent alcohol consumption. The capillary zone electrophoresis analysis of EtG in model mixtures and human serum is reported using uncoated and coated fused-silica capillaries together withacidic buffers in the pH range between 3.2 and 4.4 and indirect detection. In these approaches, separation of EtG from anionic serum components of high and low concentration is based upon transient isotachophoretic stacking. A buffer composed of 10 mM nicotinic acid and epsilon-aminocaproic acid (pH 4.3) is demonstrated to provide a detection limit for EtG in serum of 0.1 microg/ml, a value that is relevant for clinical and forensic purposes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA4031401" target="_blank" >IAA4031401: Vývoj nových optimalizačních a metodologických technik pro kapilární elektroforézu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1081
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
2-8
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—