Vliv magnetického a elektrostatického pole v oblasti vzorku na trajektorie sekundárních elektronů v REM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F04%3A00109103" target="_blank" >RIV/68081731:_____/04:00109103 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of magnetic and electrostatic fields in the specimen vicinity on trajectories of secondary electrons in SEM
Popis výsledku v původním jazyce
The Everhart-Thornley (ET) type detector is widely used in SEM for collection of secondary electrons (SE). At first glance the electrostatic field of the front grid, biased to a positive potential of several hundred volts, might be thought to attract allSE of kinetic energy below 50 eV or at least those emitted at 1-5 eV, i.e. near the SE spectrum peak. However, the detective quantum efficiency (DQE) of such detectors has been found significantly below one. Due to complicated distribution of electrostatic and magnetic fields around the specimen, which influence the SE trajectories, the DQE depends heavily on the collection efficiency (CE), i.e. the proportion of emitted species that impact on the detector. Preliminary simulations of electron trajectories indicated the CE values for the ET detector even below 0.1 for small working distances while more detailed results are reported here
Název v anglickém jazyce
Influence of magnetic and electrostatic fields in the specimen vicinity on trajectories of secondary electrons in SEM
Popis výsledku anglicky
The Everhart-Thornley (ET) type detector is widely used in SEM for collection of secondary electrons (SE). At first glance the electrostatic field of the front grid, biased to a positive potential of several hundred volts, might be thought to attract allSE of kinetic energy below 50 eV or at least those emitted at 1-5 eV, i.e. near the SE spectrum peak. However, the detective quantum efficiency (DQE) of such detectors has been found significantly below one. Due to complicated distribution of electrostatic and magnetic fields around the specimen, which influence the SE trajectories, the DQE depends heavily on the collection efficiency (CE), i.e. the proportion of emitted species that impact on the detector. Preliminary simulations of electron trajectories indicated the CE values for the ET detector even below 0.1 for small working distances while more detailed results are reported here
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA1065304" target="_blank" >IAA1065304: Mnohokanálová spektro-mikroskopie pomalými a Augerovými elektrony</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Autumn School on Materials Science and Electron Microscopy 2004 - Emerging Microscopy for Advanced Materials Development: Imaging and Spectroscopy on Atomic Scale
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
"24/1"-"24/2"
Název nakladatele
Humboldt University of Berlin
Místo vydání
Berlin
Místo konání akce
Berlin
Datum konání akce
3. 10. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—