Katodoluminiscence jako metoda studia degradace polysilanů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F06%3A00044284" target="_blank" >RIV/68081731:_____/06:00044284 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cathodoluminescence as a method for the study of degradation of polysilanes
Popis výsledku v původním jazyce
The paper presents a unique cathodoluminescent (CL) method suitable for studying polysilane properties and the first CL characteristics of the material being investigated. Poly[methyl(phenyl)silylene] (PMPSi) was selected as a typical representative of polysilanes. The PMPSi study was based on the measurement of the intensity of CL emission after passing through the specimen. The major problem of this study is the susceptibility of the material being investigated to the degradation by electron beam. PMPSi degradation strongly decreases the CL intensity. Therefore, detection in the synchronous mode was used to eliminate the influence of the background and of the noise. It was found that the degradation process is partly reversible. A partial recovery ofintensity was attributed to reverse recombination reactions of silyl radicals in a vacuum after 20 h of annealing at room temperature.
Název v anglickém jazyce
Cathodoluminescence as a method for the study of degradation of polysilanes
Popis výsledku anglicky
The paper presents a unique cathodoluminescent (CL) method suitable for studying polysilane properties and the first CL characteristics of the material being investigated. Poly[methyl(phenyl)silylene] (PMPSi) was selected as a typical representative of polysilanes. The PMPSi study was based on the measurement of the intensity of CL emission after passing through the specimen. The major problem of this study is the susceptibility of the material being investigated to the degradation by electron beam. PMPSi degradation strongly decreases the CL intensity. Therefore, detection in the synchronous mode was used to eliminate the influence of the background and of the noise. It was found that the degradation process is partly reversible. A partial recovery ofintensity was attributed to reverse recombination reactions of silyl radicals in a vacuum after 20 h of annealing at room temperature.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA100100622" target="_blank" >IAA100100622: KONJUGOVANÉ KŘEMÍKOVÉ POLYMERY PRO REZISTY V NANOTECHNOLOGIÍCH</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physical Research. B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
252
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
303-307
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—