Měření čistoty jódu v absorpčních kyvetách pro frekvenční stabilizaci laserů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F07%3A00082860" target="_blank" >RIV/68081731:_____/07:00082860 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Iodine Purity in Absorption Cells for Laser Frequency Stabilization
Popis výsledku v původním jazyce
In the contribution we present a system for measurement of iodine purity by means excitation of a selected strong transition, measurement of induced fluorescence and evaluation by the Stern-Volmer formula. The arrangement is based on a pumping Ar-ion laser tuned to the transition of interest but its linewidth far exceeds the transition. Frequency noise of the laser is effectivelly reduced by monitoring the fluorescence in a second, reference iodine cell and together with monitoring of the laser power enables cancelation of the frequency noise influence which generates errors by demodulating on the absorption profile. The level of the scattered light is subtracted as well. All the measured data are digitally processed and the experiment is fully computer controlled.
Název v anglickém jazyce
Measurement of Iodine Purity in Absorption Cells for Laser Frequency Stabilization
Popis výsledku anglicky
In the contribution we present a system for measurement of iodine purity by means excitation of a selected strong transition, measurement of induced fluorescence and evaluation by the Stern-Volmer formula. The arrangement is based on a pumping Ar-ion laser tuned to the transition of interest but its linewidth far exceeds the transition. Frequency noise of the laser is effectivelly reduced by monitoring the fluorescence in a second, reference iodine cell and together with monitoring of the laser power enables cancelation of the frequency noise influence which generates errors by demodulating on the absorption profile. The level of the scattered light is subtracted as well. All the measured data are digitally processed and the experiment is fully computer controlled.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 17th International Conference Radioelektronika 2007
ISBN
9788021433908
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
377-381
Název nakladatele
Department of Radio Electronics Brno University of Technology
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
24. 4. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—