The analysis of linear/nonlinear coupling between heart rate and QT intervals

Identifikátory výsledku

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    The analysis of linear/nonlinear coupling between heart rate and QT intervals

  • Popis výsledku v původním jazyce

    Two groups of subjects (21 healthy, 21 hypertensive patients) were tested during two measurement protocols (exercise, tilt). Two models of QT-RR coupling were tested - linear (LM) and nonlinear (NLM). QTc reproducibility was used as evidence of model validity. Results: LM was significantly better (lower QTc irreproducibility) than NLM (P<;0.01) during the tilt-table test. The differences were not significant during the exercise test; NLM was slightly better in hypertensive patients, LM in healthy subjects. Maximal irreproducibility of QTc over subjects was found in both tests with NLM. Conclusion: Evidence of QT-RR nonlinearity cannot be based on minimal error between QT and model QT. QTc reproducibility must also be tested and the excitation specificity of QT-RR coupling must be considered.Two groups of subjects (21 healthy, 21 hypertensive patients) were tested during two measurement protocols (exercise, tilt). Two models of QT-RR coupling were tested - linear (LM) and nonlinear (NLM

  • Název v anglickém jazyce

    The analysis of linear/nonlinear coupling between heart rate and QT intervals

  • Popis výsledku anglicky

    Two groups of subjects (21 healthy, 21 hypertensive patients) were tested during two measurement protocols (exercise, tilt). Two models of QT-RR coupling were tested - linear (LM) and nonlinear (NLM). QTc reproducibility was used as evidence of model validity. Results: LM was significantly better (lower QTc irreproducibility) than NLM (P<;0.01) during the tilt-table test. The differences were not significant during the exercise test; NLM was slightly better in hypertensive patients, LM in healthy subjects. Maximal irreproducibility of QTc over subjects was found in both tests with NLM. Conclusion: Evidence of QT-RR nonlinearity cannot be based on minimal error between QT and model QT. QTc reproducibility must also be tested and the excitation specificity of QT-RR coupling must be considered.Two groups of subjects (21 healthy, 21 hypertensive patients) were tested during two measurement protocols (exercise, tilt). Two models of QT-RR coupling were tested - linear (LM) and nonlinear (NLM

Klasifikace

  • Druh

    D - Stať ve sborníku

  • CEP obor

    JA - Elektronika a optoelektronika, elektrotechnika

  • OECD FORD obor

Návaznosti výsledku

Ostatní

  • Rok uplatnění

    2014

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název statě ve sborníku

    8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO 2014)

  • ISBN

    978-1-4799-3968-8

  • ISSN

  • e-ISSN

  • Počet stran výsledku

    2

  • Strana od-do

    59-60

  • Název nakladatele

    IEEE

  • Místo vydání

    Trento

  • Místo konání akce

    Trento

  • Datum konání akce

    25. 5. 2014

  • Typ akce podle státní příslušnosti

    WRD - Celosvětová akce

  • Kód UT WoS článku

    000343599700030

Druh výsledku

D - Stať ve sborníku

D

CEP

JA - Elektronika a optoelektronika, elektrotechnika

Rok uplatnění

2014