Excitation Specificity of Repolarization Parameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00431911" target="_blank" >RIV/68081731:_____/14:00431911 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Excitation Specificity of Repolarization Parameters
Popis výsledku v původním jazyce
QT/RR coupling was analyzed in two groups of subjects (healthy and hypertensive) with two protocols (exercise and tilt). A dynamic model of QT/RR coupling with 3 optimized parameters was used to analyze dynamic properties (memory and restitution) and toeliminate QT hysteresis. Linear and nonlinear models were used to analyze static properties. Parameter reproducibility was tested by a bootstrap methodology. The linear model is better with the tilt test, the nonlinear model is better in hypertensive patients with the exercise test. QT memory differs significantly between the exercise and tilt test in both groups. The QT/RR slope is steeper in the exercise test and QT adaptation faster with the tilt test. The excitation specificity of QT parameters mayexplain genetic dependent triggers of arrhythmias and QT/RR nonlinearity.
Název v anglickém jazyce
Excitation Specificity of Repolarization Parameters
Popis výsledku anglicky
QT/RR coupling was analyzed in two groups of subjects (healthy and hypertensive) with two protocols (exercise and tilt). A dynamic model of QT/RR coupling with 3 optimized parameters was used to analyze dynamic properties (memory and restitution) and toeliminate QT hysteresis. Linear and nonlinear models were used to analyze static properties. Parameter reproducibility was tested by a bootstrap methodology. The linear model is better with the tilt test, the nonlinear model is better in hypertensive patients with the exercise test. QT memory differs significantly between the exercise and tilt test in both groups. The QT/RR slope is steeper in the exercise test and QT adaptation faster with the tilt test. The excitation specificity of QT parameters mayexplain genetic dependent triggers of arrhythmias and QT/RR nonlinearity.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F12%2F2034" target="_blank" >GAP102/12/2034: Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electrocardiology 2014. Proceedings of the 41st International Congress on Electrocardiology
ISBN
978-80-969672-7-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
15-18
Název nakladatele
Institute of Measurement Science
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
4. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—