Excitation Specificity of Repolarization Parameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F11%3A00368135" target="_blank" >RIV/68081731:_____/11:00368135 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Excitation Specificity of Repolarization Parameters
Popis výsledku v původním jazyce
The excitation specificity of QT dynamic parameters was tested on three groups of subjects: healthy subjects; non-medicated hypertensive subjects with metabolic syndrome; and subjects with essential hypertension. Four different excitations of RR were used: bicycling exercise; tilt with breathing 0.1 and 0.33 Hz; and deep breathing. Linear dynamic feedback model of QT/RR coupling was supposed at the analysis and next repolarization parameters were tested: QTc; gain of QT/RR coupling for slow and fast RRvariability; time constant of QT adaptation; and random QT variability. Results: Dynamic repolarization parameters statistically significantly depend on the type of RR excitation. The gain of QT/RR coupling for slow RR variability, the time constant of QT adaptation and QTc are maximal at RR excitation given by the bicycling exercise. The frequency of breathing, i.e. corresponding vagal modulation has no effect on repolarization parameters.
Název v anglickém jazyce
Excitation Specificity of Repolarization Parameters
Popis výsledku anglicky
The excitation specificity of QT dynamic parameters was tested on three groups of subjects: healthy subjects; non-medicated hypertensive subjects with metabolic syndrome; and subjects with essential hypertension. Four different excitations of RR were used: bicycling exercise; tilt with breathing 0.1 and 0.33 Hz; and deep breathing. Linear dynamic feedback model of QT/RR coupling was supposed at the analysis and next repolarization parameters were tested: QTc; gain of QT/RR coupling for slow and fast RRvariability; time constant of QT adaptation; and random QT variability. Results: Dynamic repolarization parameters statistically significantly depend on the type of RR excitation. The gain of QT/RR coupling for slow RR variability, the time constant of QT adaptation and QTc are maximal at RR excitation given by the bicycling exercise. The frequency of breathing, i.e. corresponding vagal modulation has no effect on repolarization parameters.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME09050" target="_blank" >ME09050: Analýza dynamických a statických vlastností QT intervalů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
33rd Annual International IEEE EMBS Conference
ISBN
978-1-4244-4122-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
961-964
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Boston
Datum konání akce
30. 8. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—