An additional marker of ventricular dyssynchrony
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F15%3A00456399" target="_blank" >RIV/68081731:_____/15:00456399 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An additional marker of ventricular dyssynchrony
Popis výsledku v původním jazyce
Patients suffering from heart failure with left bundle branch block (LBBB) can be effectively treated by resynchronization therapy (CRT). The ejection fraction, QRS duration (QRSd) and QRS morphology are the main selection criteria. Unfortunately, approximately one-third of CRT recipients are non-responders. Here we introduce an additional marker capable of distinguishing ventricular dyssynchrony more accurately. Methods: Ultra-high-frequency (UHF, sampling 25 kHz) 12-lead ECG, resting supine position,was measured. We analyzed 21 LBBB patients selected for CRT; the QRSd min/mean/max was 130/163/190 ms. Amplitude envelopes in the 500?1,000 Hz passband were computed and averaged with an R-wave trigger for each patient in the V1 and V6 leads. V1-V6 dyssynchrony (DYS) was computed as the time difference between UHF amplitude maximums in the V1 and V6 QRS complex region. The DYS parameter min/mean/max was 1/68/115 ms. Patients with a small value of the DYS parameter, in spite of the fact t
Název v anglickém jazyce
An additional marker of ventricular dyssynchrony
Popis výsledku anglicky
Patients suffering from heart failure with left bundle branch block (LBBB) can be effectively treated by resynchronization therapy (CRT). The ejection fraction, QRS duration (QRSd) and QRS morphology are the main selection criteria. Unfortunately, approximately one-third of CRT recipients are non-responders. Here we introduce an additional marker capable of distinguishing ventricular dyssynchrony more accurately. Methods: Ultra-high-frequency (UHF, sampling 25 kHz) 12-lead ECG, resting supine position,was measured. We analyzed 21 LBBB patients selected for CRT; the QRSd min/mean/max was 130/163/190 ms. Amplitude envelopes in the 500?1,000 Hz passband were computed and averaged with an R-wave trigger for each patient in the V1 and V6 leads. V1-V6 dyssynchrony (DYS) was computed as the time difference between UHF amplitude maximums in the V1 and V6 QRS complex region. The DYS parameter min/mean/max was 1/68/115 ms. Patients with a small value of the DYS parameter, in spite of the fact t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology 2015. Vol. 42
ISBN
978-1-5090-0685-4
ISSN
2325-8861
e-ISSN
—
Počet stran výsledku
4
Strana od-do
77-80
Název nakladatele
Computing in Cardiology
Místo vydání
Cambridge
Místo konání akce
Nice
Datum konání akce
6. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—