Biventricular pacing optimization by means of the dyssynchrony parameter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00474791" target="_blank" >RIV/68081731:_____/16:00474791 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.22489/CinC.2016.051-263" target="_blank" >http://dx.doi.org/10.22489/CinC.2016.051-263</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22489/CinC.2016.051-263" target="_blank" >10.22489/CinC.2016.051-263</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biventricular pacing optimization by means of the dyssynchrony parameter
Popis výsledku v původním jazyce
To improve Cardiac Resynchronization Therapy (CRT), different interventricular delay (VVD) settings can be used. However, relatively small VVD induced hemodynamic changes cannot be measured by standard echocardiographic methods. The QRS complex duration (QRSd) is mostly the main criterion. Here we introduce a new dyssynchrony parameter (DYS) that is able to more accurately detect improved electrical synchrony. Methods: 12-lead 5 kHz ECG during 3-10 minute rest period was measured in 46 patients with CRT OFF and CRT ON with VVD 0 ms (CRT0) and -20 ms (CRT20). We detected QRSd and the dyssynchrony parameter DYS as the time difference between 500-1000 Hz averaged envelopes positions in the V1 and V6 leads in the QRS complex region. Results: 32 of 46 patients had a positive CRT response manifested by QRSd shortening and a DYS decrease. 28 of 32 patients had a positive LV pre-excitation effect: additional QRSd shortening of 4.7+/-.9 ms and a DYS decrease of 12.6+/-7.5 ms. The correlation coefficient of QRSd and DYS changes (CRT 0 vs CRT 20) was 0.23 and indicates information diversity. The DYS parameter differs from QRSd and provides a significantly higher response to VVdelay changes (p <, 0.001).
Název v anglickém jazyce
Biventricular pacing optimization by means of the dyssynchrony parameter
Popis výsledku anglicky
To improve Cardiac Resynchronization Therapy (CRT), different interventricular delay (VVD) settings can be used. However, relatively small VVD induced hemodynamic changes cannot be measured by standard echocardiographic methods. The QRS complex duration (QRSd) is mostly the main criterion. Here we introduce a new dyssynchrony parameter (DYS) that is able to more accurately detect improved electrical synchrony. Methods: 12-lead 5 kHz ECG during 3-10 minute rest period was measured in 46 patients with CRT OFF and CRT ON with VVD 0 ms (CRT0) and -20 ms (CRT20). We detected QRSd and the dyssynchrony parameter DYS as the time difference between 500-1000 Hz averaged envelopes positions in the V1 and V6 leads in the QRS complex region. Results: 32 of 46 patients had a positive CRT response manifested by QRSd shortening and a DYS decrease. 28 of 32 patients had a positive LV pre-excitation effect: additional QRSd shortening of 4.7+/-.9 ms and a DYS decrease of 12.6+/-7.5 ms. The correlation coefficient of QRSd and DYS changes (CRT 0 vs CRT 20) was 0.23 and indicates information diversity. The DYS parameter differs from QRSd and provides a significantly higher response to VVdelay changes (p <, 0.001).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology (CinC) 2016
ISBN
978-1-5090-0896-4
ISSN
2325-8861
e-ISSN
—
Počet stran výsledku
4
Strana od-do
165-168
Název nakladatele
Computing in Cardiology
Místo vydání
Vencouver
Místo konání akce
Vencouver
Datum konání akce
11. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000405710400042