High resolution kilometric range optical telemetry in air by radio frequency phase measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00463094" target="_blank" >RIV/68081731:_____/16:00463094 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4954180" target="_blank" >http://dx.doi.org/10.1063/1.4954180</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4954180" target="_blank" >10.1063/1.4954180</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High resolution kilometric range optical telemetry in air by radio frequency phase measurement
Popis výsledku v původním jazyce
We have developed an optical Absolute Distance Meter (ADM) based on the measurement of the phase accumulated by a Radio Frequency wave during its propagation in the air by a laser beam. In this article, the ADM principle will be described and the main results will be presented. In particular, we will emphasize how the choice of an appropriate photodetector can significantly improve the telemeter performances by minimizing the amplitude to phase conversion. Our prototype, tested in the field, has proven its efficiency with a resolution better than 15 μm for a measurement time of 10 ms and distances up to 1.2 km.
Název v anglickém jazyce
High resolution kilometric range optical telemetry in air by radio frequency phase measurement
Popis výsledku anglicky
We have developed an optical Absolute Distance Meter (ADM) based on the measurement of the phase accumulated by a Radio Frequency wave during its propagation in the air by a laser beam. In this article, the ADM principle will be described and the main results will be presented. In particular, we will emphasize how the choice of an appropriate photodetector can significantly improve the telemeter performances by minimizing the amplitude to phase conversion. Our prototype, tested in the field, has proven its efficiency with a resolution better than 15 μm for a measurement time of 10 ms and distances up to 1.2 km.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
87
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
"075105:1"-"6"
Kód UT WoS článku
000382448600055
EID výsledku v databázi Scopus
—