Using multichannel blind AIF estimation with the DCATH model to allow increased temporal sampling interval in DCE-MRI
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00466408" target="_blank" >RIV/68081731:_____/16:00466408 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985556:_____/16:00466408
Výsledek na webu
<a href="http://link.springer.com/journal/10334/29/1/suppl/page/1" target="_blank" >http://link.springer.com/journal/10334/29/1/suppl/page/1</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using multichannel blind AIF estimation with the DCATH model to allow increased temporal sampling interval in DCE-MRI
Popis výsledku v původním jazyce
Dynamic contrast-enhanced (DCE) MRI is used for estimation of tissue perfusion parameters, mainly in oncology. Quantitative DCE-MRI analysis requires knowledge of the arterial input function (AIF). It can be measured from a feeding artery, eventually averaged over a population. This leads to partialvolume and flow artifacts, ignored dispersion terms and variability among patients. Multichannel blind deconvolution is an alternative approach avoiding these problems. The AIF is estimated from several tissue tracer concentration curves. Here, blind deconvolution with a parametric AIF model is used to allow lower temporal resolution in DCE-MRI acquisition, while maintaining the accuracy of perfusion analysis. Compared to, a more complex (higher sampling demands) model for impulse residue function (IRF), DCATH, is used.
Název v anglickém jazyce
Using multichannel blind AIF estimation with the DCATH model to allow increased temporal sampling interval in DCE-MRI
Popis výsledku anglicky
Dynamic contrast-enhanced (DCE) MRI is used for estimation of tissue perfusion parameters, mainly in oncology. Quantitative DCE-MRI analysis requires knowledge of the arterial input function (AIF). It can be measured from a feeding artery, eventually averaged over a population. This leads to partialvolume and flow artifacts, ignored dispersion terms and variability among patients. Multichannel blind deconvolution is an alternative approach avoiding these problems. The AIF is estimated from several tissue tracer concentration curves. Here, blind deconvolution with a parametric AIF model is used to allow lower temporal resolution in DCE-MRI acquisition, while maintaining the accuracy of perfusion analysis. Compared to, a more complex (higher sampling demands) model for impulse residue function (IRF), DCATH, is used.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Magma
ISBN
—
ISSN
1352-8661
e-ISSN
—
Počet stran výsledku
2
Strana od-do
"S288"-"S289"
Název nakladatele
Springer
Místo vydání
Berlin
Místo konání akce
Vienna
Datum konání akce
29. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—