Custom: terminated multimode fibre probe for holographic micro-endoscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F22%3A00568082" target="_blank" >RIV/68081731:_____/22:00568082 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12502/2664219/Custom-terminated-multimode-fibre-probe-for-holographic-micro-endoscopy/10.1117/12.2664219.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12502/2664219/Custom-terminated-multimode-fibre-probe-for-holographic-micro-endoscopy/10.1117/12.2664219.short</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2664219" target="_blank" >10.1117/12.2664219</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Custom: terminated multimode fibre probe for holographic micro-endoscopy
Popis výsledku v původním jazyce
Using multiphoton microscopy, we can image the tissue with sub-cellular resolution at depths down to 1.5 mm. Beyond this reach, the light must be delivered to the target region by optical relay elements inserted into the tissue the endoscopes. Focusing light through a step-index multimode optical fibre (MMF) using wave-front control enables minimally-invasive endoscopy. With fibre micro-endoscopes, we can reach any depth with negligible tissue disruption and keep the resolution below 1 micrometre, sufficient for in vivo microscopy. We designed a novel custom-terminated multimode fibre probe. This work will focus on optical fibre probe manufacturing methods (etching, polishing and coating) and their impact on imaging quality.
Název v anglickém jazyce
Custom: terminated multimode fibre probe for holographic micro-endoscopy
Popis výsledku anglicky
Using multiphoton microscopy, we can image the tissue with sub-cellular resolution at depths down to 1.5 mm. Beyond this reach, the light must be delivered to the target region by optical relay elements inserted into the tissue the endoscopes. Focusing light through a step-index multimode optical fibre (MMF) using wave-front control enables minimally-invasive endoscopy. With fibre micro-endoscopes, we can reach any depth with negligible tissue disruption and keep the resolution below 1 micrometre, sufficient for in vivo microscopy. We designed a novel custom-terminated multimode fibre probe. This work will focus on optical fibre probe manufacturing methods (etching, polishing and coating) and their impact on imaging quality.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000476" target="_blank" >EF15_003/0000476: Holografická endoskopie pro in vivo aplikace</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
22nd Polish-Slovak-Czech Optical Conference on Wave and Quantum Aspects of Contemporary Optics
ISBN
978-1-5106-6112-7
ISSN
0277-786X
e-ISSN
1996-756X
Počet stran výsledku
5
Strana od-do
1250211
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Wojanów
Datum konání akce
5. 9. 2022
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000920988700036