Development of a real-time dose monitor with Cr-doped Gd3Ga5O12 infrared scintillator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F17%3A00483144" target="_blank" >RIV/68378271:_____/17:00483144 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2017.03.028" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2017.03.028</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2017.03.028" target="_blank" >10.1016/j.radmeas.2017.03.028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of a real-time dose monitor with Cr-doped Gd3Ga5O12 infrared scintillator
Popis výsledku v původním jazyce
In this study, a novel infrared scintillator, Cr-doped Gd3Ga5O12, was tested with pork meat as a phantom of human tissue to prove its feasibility for the dose monitor. The scintillation photons of Cr:Gd3Ga5O12 were observed through even 50-mm thick pork meat. The emission peak originated from d-d emission of Cr3+,. The emission intensity of Cr:Gd3Ga5O12 was approximately 3.5 times larger than that of the conventional infrared scintillator Cr:α-Al2O3. Moreover, we succeeded in performing the infrared imaging for Cr:Gd3Ga5O12 irradiated with alpha-rays using a complementary metal oxide semiconductor camera.n
Název v anglickém jazyce
Development of a real-time dose monitor with Cr-doped Gd3Ga5O12 infrared scintillator
Popis výsledku anglicky
In this study, a novel infrared scintillator, Cr-doped Gd3Ga5O12, was tested with pork meat as a phantom of human tissue to prove its feasibility for the dose monitor. The scintillation photons of Cr:Gd3Ga5O12 were observed through even 50-mm thick pork meat. The emission peak originated from d-d emission of Cr3+,. The emission intensity of Cr:Gd3Ga5O12 was approximately 3.5 times larger than that of the conventional infrared scintillator Cr:α-Al2O3. Moreover, we succeeded in performing the infrared imaging for Cr:Gd3Ga5O12 irradiated with alpha-rays using a complementary metal oxide semiconductor camera.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
106
Číslo periodika v rámci svazku
Nov
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
187-191
Kód UT WoS článku
000419417500035
EID výsledku v databázi Scopus
2-s2.0-85016567115