Modelling radiation damage to pixel sensors in the ATLAS detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F19%3A00520474" target="_blank" >RIV/68378271:_____/19:00520474 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/19:00339233 RIV/68407700:21340/19:00339233 RIV/68407700:21670/19:00339233 RIV/00216208:11320/19:10407524 RIV/61989592:15310/19:73596237
Výsledek na webu
<a href="http://hdl.handle.net/11104/0305145" target="_blank" >http://hdl.handle.net/11104/0305145</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/06/P06012" target="_blank" >10.1088/1748-0221/14/06/P06012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modelling radiation damage to pixel sensors in the ATLAS detector
Popis výsledku v původním jazyce
Silicon pixel detectors are at the core of the current and planned upgrade of the ATLAS experiment at the LHC. Given their close proximity to the interaction point, these detectors will be exposed to an unprecedented amount of radiation over their lifetime. The current pixel detector will receive damage from non-ionizing radiation in excess of 1015 1 MeV neq/cm2, while the pixel detector designed for the high-luminosity LHC must cope with an order of magnitude larger fluence. This paper presents a digitization model incorporating effects of radiation damage to the pixel sensors. The model is described in detail and predictions for the charge collection efficiency and Lorentz angle are compared with collision data collected between 2015 and 2017 (≤ 1015 1 MeV neq/cm2).n
Název v anglickém jazyce
Modelling radiation damage to pixel sensors in the ATLAS detector
Popis výsledku anglicky
Silicon pixel detectors are at the core of the current and planned upgrade of the ATLAS experiment at the LHC. Given their close proximity to the interaction point, these detectors will be exposed to an unprecedented amount of radiation over their lifetime. The current pixel detector will receive damage from non-ionizing radiation in excess of 1015 1 MeV neq/cm2, while the pixel detector designed for the high-luminosity LHC must cope with an order of magnitude larger fluence. This paper presents a digitization model incorporating effects of radiation damage to the pixel sensors. The model is described in detail and predictions for the charge collection efficiency and Lorentz angle are compared with collision data collected between 2015 and 2017 (≤ 1015 1 MeV neq/cm2).n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
53
Strana od-do
1-53
Kód UT WoS článku
000472134700001
EID výsledku v databázi Scopus
2-s2.0-85070359632