Electrical characterization of surface properties of the ATLAS17LS sensors after neutron, proton and gamma irradiation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F20%3A00535635" target="_blank" >RIV/68378271:_____/20:00535635 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/20:00347600 RIV/00216208:11320/20:10424413
Výsledek na webu
<a href="https://doi.org/10.1016/j.nima.2020.164456" target="_blank" >https://doi.org/10.1016/j.nima.2020.164456</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2020.164456" target="_blank" >10.1016/j.nima.2020.164456</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrical characterization of surface properties of the ATLAS17LS sensors after neutron, proton and gamma irradiation
Popis výsledku v původním jazyce
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2027, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected total integrated luminosity of 4000 fb-1 means that the strip part of the ITk detector will be exposed to a large radiation fluence of up to Φeq = 1.6×1015 1 MeV neq/cm and an ionizing dose of 0.66 MGy, including a safety factor of 1.5. Radiation-hard n+-in-p micro-strip sensors for use in the ITk have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics K.K. In this paper, the results obtained from the electrical characterization of the latest barrel ATLAS17LS sensor prototype, before and after irradiation, are shown. Surface properties of the long-strip barrel, full-sized and miniature sensors have been studied before and after proton, neutron and gamma irradiation up to the maximal fluences and radiation doses specified for theITk Strip tracker. Sensors have been irradiated by protons at CYRIC, Tohoku University (Japan), the ProtonIrradiation Facility at CERN, Karlsruhe Inst. Tech. (Germany) and at the University of Birmingham (UK), by neutrons from the Ljubljana TRIGA reactor (Slovenia) and by gamma rays from the 60Co source in UJP Praha(Czech Republic). It has been verified that the surface radiation damage does not influence the sensor functionality. The breakdown voltage is well above the maximum operational voltage. All the tested surface parameters, such as the inter-strip resistance and capacitance, coupling capacitance and bias resistance satisfy the ATLAS ITk specifications for strip sensors.
Název v anglickém jazyce
Electrical characterization of surface properties of the ATLAS17LS sensors after neutron, proton and gamma irradiation
Popis výsledku anglicky
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2027, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected total integrated luminosity of 4000 fb-1 means that the strip part of the ITk detector will be exposed to a large radiation fluence of up to Φeq = 1.6×1015 1 MeV neq/cm and an ionizing dose of 0.66 MGy, including a safety factor of 1.5. Radiation-hard n+-in-p micro-strip sensors for use in the ITk have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics K.K. In this paper, the results obtained from the electrical characterization of the latest barrel ATLAS17LS sensor prototype, before and after irradiation, are shown. Surface properties of the long-strip barrel, full-sized and miniature sensors have been studied before and after proton, neutron and gamma irradiation up to the maximal fluences and radiation doses specified for theITk Strip tracker. Sensors have been irradiated by protons at CYRIC, Tohoku University (Japan), the ProtonIrradiation Facility at CERN, Karlsruhe Inst. Tech. (Germany) and at the University of Birmingham (UK), by neutrons from the Ljubljana TRIGA reactor (Slovenia) and by gamma rays from the 60Co source in UJP Praha(Czech Republic). It has been verified that the surface radiation damage does not influence the sensor functionality. The breakdown voltage is well above the maximum operational voltage. All the tested surface parameters, such as the inter-strip resistance and capacitance, coupling capacitance and bias resistance satisfy the ATLAS ITk specifications for strip sensors.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
983
Číslo periodika v rámci svazku
Dec
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
000581808300003
EID výsledku v databázi Scopus
2-s2.0-85089569735