Mass spectrometry of heavy analytes and large biological aggregates by monitoring changes in the quality factor of nanomechanical resonators in air
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F20%3A00563767" target="_blank" >RIV/68378271:_____/20:00563767 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/20:PU136929 RIV/00216208:11110/20:10426396
Výsledek na webu
<a href="https://doi.org/10.1021/acssensors.0c00756" target="_blank" >https://doi.org/10.1021/acssensors.0c00756</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acssensors.0c00756" target="_blank" >10.1021/acssensors.0c00756</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mass spectrometry of heavy analytes and large biological aggregates by monitoring changes in the quality factor of nanomechanical resonators in air
Popis výsledku v původním jazyce
Nanomechanical resonators are routinely used for identification of various analytes such as biological and chemical molecules, viruses, or bacteria cells from the frequency response. This identification based on the multimode frequency shift measurement is limited to the analyte of mass that is much lighter than the resonator mass. Hence, the analyte can be modeled as a point particle and, as such, its stiffness and nontrivial binding effects such as surface stress can be neglected. For heavy analytes (>MDa), this identification, however, leads to incorrectly estimated masses.
Název v anglickém jazyce
Mass spectrometry of heavy analytes and large biological aggregates by monitoring changes in the quality factor of nanomechanical resonators in air
Popis výsledku anglicky
Nanomechanical resonators are routinely used for identification of various analytes such as biological and chemical molecules, viruses, or bacteria cells from the frequency response. This identification based on the multimode frequency shift measurement is limited to the analyte of mass that is much lighter than the resonator mass. Hence, the analyte can be modeled as a point particle and, as such, its stiffness and nontrivial binding effects such as surface stress can be neglected. For heavy analytes (>MDa), this identification, however, leads to incorrectly estimated masses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000760" target="_blank" >EF16_019/0000760: Fyzika pevných látek pro 21. století</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ACS Sensors
ISSN
2379-3694
e-ISSN
2379-3694
Svazek periodika
5
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
2128-2135
Kód UT WoS článku
000573554900034
EID výsledku v databázi Scopus
2-s2.0-85088608259