Deformation analysis of the spongious sample in simulated physiological conditions based on in-situncompression, 4D computed tomography and fast readout detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F18%3A00497305" target="_blank" >RIV/68378297:_____/18:00497305 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/13/11/C11021" target="_blank" >https://doi.org/10.1088/1748-0221/13/11/C11021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/13/11/C11021" target="_blank" >10.1088/1748-0221/13/11/C11021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Deformation analysis of the spongious sample in simulated physiological conditions based on in-situncompression, 4D computed tomography and fast readout detector
Popis výsledku v původním jazyce
In this work, an in-house designed table top loading device equipped with a bioreactor is used for the in-situ compression of a spongious sample in simulated physiological conditions. On-the-fly 4D computed tomography is used as a tool for the advanced volumetric analysis of the deforming microstructure of the specimen. The loading device with the bioreactor was placed directly onto the rotational stage of a modular X-ray scanner. As the loading device is equipped with a slip-ring cable system, it can perform an unlimited number of revolutions during the on-the-fly scanning procedure. A complementary metal-oxide-semiconductor flat panel detector with a fast readout was used for the acquisition of the X-ray images. The specimen was compressed with a low loading velocity. A set of the volumetric data capturing the deformation of the specimen during the experiment was prepared from the images acquired by the detector. A digital volume correlation algorithm was used for the evaluation of the volumetric strain fields in the specimen.
Název v anglickém jazyce
Deformation analysis of the spongious sample in simulated physiological conditions based on in-situncompression, 4D computed tomography and fast readout detector
Popis výsledku anglicky
In this work, an in-house designed table top loading device equipped with a bioreactor is used for the in-situ compression of a spongious sample in simulated physiological conditions. On-the-fly 4D computed tomography is used as a tool for the advanced volumetric analysis of the deforming microstructure of the specimen. The loading device with the bioreactor was placed directly onto the rotational stage of a modular X-ray scanner. As the loading device is equipped with a slip-ring cable system, it can perform an unlimited number of revolutions during the on-the-fly scanning procedure. A complementary metal-oxide-semiconductor flat panel detector with a fast readout was used for the acquisition of the X-ray images. The specimen was compressed with a low loading velocity. A set of the volumetric data capturing the deformation of the specimen during the experiment was prepared from the images acquired by the detector. A digital volume correlation algorithm was used for the evaluation of the volumetric strain fields in the specimen.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Inženýrské aplikace fyziky mikrosvěta</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000451408400003
EID výsledku v databázi Scopus
2-s2.0-85057604044