The effectiveness of a low height noise barrier
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00219828" target="_blank" >RIV/68407700:21110/14:00219828 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The effectiveness of a low height noise barrier
Popis výsledku v původním jazyce
Due to the ever growing demands for health protection from the adverse effects of noise and vibrations, the production of various types of noise control measures has been rising. In the spring of 2013, a low height noise barrier (LHNB) was used along a railway line in the Czech Republic for the first time. This barrier was placed along a 214 m long test section of a railway track (No. 520 A) in Prague ? Hlubočepy. The study (Analysis of the Effectiveness of a Low Height Noise Barrier along a Section ofthe Hlubočepy ? Rudná Railway Line) included the evaluation of the effectiveness of the low acoustic screen in terms of noise emissions in the respective area. Direct in-situ measurement at two measured points of the investigated section along a railwayline was performed before and, successively, after the installation of low height noise barriers. The measured values of equivalent A?weighted sound pressure levels LAeq were used to determine the acoustic effectiveness of the newly built
Název v anglickém jazyce
The effectiveness of a low height noise barrier
Popis výsledku anglicky
Due to the ever growing demands for health protection from the adverse effects of noise and vibrations, the production of various types of noise control measures has been rising. In the spring of 2013, a low height noise barrier (LHNB) was used along a railway line in the Czech Republic for the first time. This barrier was placed along a 214 m long test section of a railway track (No. 520 A) in Prague ? Hlubočepy. The study (Analysis of the Effectiveness of a Low Height Noise Barrier along a Section ofthe Hlubočepy ? Rudná Railway Line) included the evaluation of the effectiveness of the low acoustic screen in terms of noise emissions in the respective area. Direct in-situ measurement at two measured points of the investigated section along a railwayline was performed before and, successively, after the installation of low height noise barriers. The measured values of equivalent A?weighted sound pressure levels LAeq were used to determine the acoustic effectiveness of the newly built
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
14th GeoConference on ECOLOGY, ECONOMICS, EDUCATION AND LEGISLATION
ISBN
978-619-7105-18-6
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
8
Strana od-do
711-718
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
17. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—