Bond Characteristics of TRC Slabs Cured in Autoclave
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00309989" target="_blank" >RIV/68407700:21110/17:00309989 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.722.305" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.722.305</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.722.305" target="_blank" >10.4028/www.scientific.net/KEM.722.305</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bond Characteristics of TRC Slabs Cured in Autoclave
Popis výsledku v původním jazyce
Textile reinforced concrete (TRC) found its application in real practice and several producers and companies included TRC 's elements into their production program. The most popular and widespread are slim façade panels with high aesthetic quality and excellent durability. Curing conditions influence the final properties, which is important especially in precast production where special devices can be used. This paper deals with experimental investigation of bond characteristics of slabs made from TRC hydrothermally cured in autoclave device and reference slabs cured in laboratory conditions for 28 days. Dimension of TRC slabs was 230 x 100 x 20 mm. Compressive strength 100 MPa characterizes used cement matrix (laboratory cured after 28 days). Basalt and AR-glass fabrics with different properties were used as reinforcement. Three-points bending test with clear span of supports 200 mm evaluated maximum bond capacity and load-deflection diagrams described character of failure and ductility.
Název v anglickém jazyce
Bond Characteristics of TRC Slabs Cured in Autoclave
Popis výsledku anglicky
Textile reinforced concrete (TRC) found its application in real practice and several producers and companies included TRC 's elements into their production program. The most popular and widespread are slim façade panels with high aesthetic quality and excellent durability. Curing conditions influence the final properties, which is important especially in precast production where special devices can be used. This paper deals with experimental investigation of bond characteristics of slabs made from TRC hydrothermally cured in autoclave device and reference slabs cured in laboratory conditions for 28 days. Dimension of TRC slabs was 230 x 100 x 20 mm. Compressive strength 100 MPa characterizes used cement matrix (laboratory cured after 28 days). Basalt and AR-glass fabrics with different properties were used as reinforcement. Three-points bending test with clear span of supports 200 mm evaluated maximum bond capacity and load-deflection diagrams described character of failure and ductility.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Special Concrete and Composites 2016
ISBN
978-3-0357-1079-3
ISSN
1013-9826
e-ISSN
1662-9795
Počet stran výsledku
6
Strana od-do
305-310
Název nakladatele
Trans Tech Publications
Místo vydání
Curich
Místo konání akce
Bystřice nad Pernštejnem, Lísek
Datum konání akce
13. 10. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—