Numerical Identification of Orthotropic Coefficients of the Lamella of a Bone's Osteon
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00201531" target="_blank" >RIV/68407700:21220/12:00201531 - isvavai.cz</a>
Výsledek na webu
<a href="http://bulletin-am.cz/index.php/vam/issue/view/34" target="_blank" >http://bulletin-am.cz/index.php/vam/issue/view/34</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical Identification of Orthotropic Coefficients of the Lamella of a Bone's Osteon
Popis výsledku v původním jazyce
Motivated by the findings of mechanical elastic coefficients of unfolded osteon lamella, a mathematical model has been developed. The unknown elastic coefficients of an osteon lamella are computed in a special way in the continuum mechanics field from the known elastic coefficients of the cortical bone as an integral whole. Due to the fact that this problem is in the level of nanometer, it is not possible at the present time to measure these elastic coefficients of the osteon lamella with high precisionvia experimental measurement. Therefore, the values derived from the mathematical model will help, among other factors, validate the accuracy of future experimental methods.
Název v anglickém jazyce
Numerical Identification of Orthotropic Coefficients of the Lamella of a Bone's Osteon
Popis výsledku anglicky
Motivated by the findings of mechanical elastic coefficients of unfolded osteon lamella, a mathematical model has been developed. The unknown elastic coefficients of an osteon lamella are computed in a special way in the continuum mechanics field from the known elastic coefficients of the cortical bone as an integral whole. Due to the fact that this problem is in the level of nanometer, it is not possible at the present time to measure these elastic coefficients of the osteon lamella with high precisionvia experimental measurement. Therefore, the values derived from the mathematical model will help, among other factors, validate the accuracy of future experimental methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI3%2F221" target="_blank" >FR-TI3/221: *Řešení problematiky necementované náhrady kolenního kloubu,optimalizace vazby implantát osteointegrační povrch kostní tkáň.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bulletin of Applied Mechanics
ISSN
1801-1217
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
31
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
45-53
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—