Mechanical behavior of bovine nasal cartilage under static and dynamic loading
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00206684" target="_blank" >RIV/68407700:21220/13:00206684 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jbiomech.2013.07.001" target="_blank" >http://dx.doi.org/10.1016/j.jbiomech.2013.07.001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jbiomech.2013.07.001" target="_blank" >10.1016/j.jbiomech.2013.07.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mechanical behavior of bovine nasal cartilage under static and dynamic loading
Popis výsledku v původním jazyce
Abnormal mechanical loading may trigger cartilage degeneration associated with osteoarthritis. Tissue response to load has been the subject of several in vitro studies. However, simple stimuli were often applied, not fully mimicking the complex in vivo conditions. Therefore, a rolling/plowing explant test system (RPETS) was developed to replicate the combined in vivo loading patterns. In this work we investigated the mechanical behavior of bovine nasal septum (BNS) cartilage, selected as tissue approximation for experiments with RPETS, under static and dynamic loading. Biphasic material properties were determined and compared with those of other cartilaginous tissues. Furthermore, dynamic loading in plowing modality was performed to determine dynamic response and experimental results were compared with analytical models and Finite Elements (FE) computations. Results showed that BNS cartilage can be modeled as a biphasic material with Young's modulus E=2.03?0.7 MPa, aggregate modulus HA
Název v anglickém jazyce
Mechanical behavior of bovine nasal cartilage under static and dynamic loading
Popis výsledku anglicky
Abnormal mechanical loading may trigger cartilage degeneration associated with osteoarthritis. Tissue response to load has been the subject of several in vitro studies. However, simple stimuli were often applied, not fully mimicking the complex in vivo conditions. Therefore, a rolling/plowing explant test system (RPETS) was developed to replicate the combined in vivo loading patterns. In this work we investigated the mechanical behavior of bovine nasal septum (BNS) cartilage, selected as tissue approximation for experiments with RPETS, under static and dynamic loading. Biphasic material properties were determined and compared with those of other cartilaginous tissues. Furthermore, dynamic loading in plowing modality was performed to determine dynamic response and experimental results were compared with analytical models and Finite Elements (FE) computations. Results showed that BNS cartilage can be modeled as a biphasic material with Young's modulus E=2.03?0.7 MPa, aggregate modulus HA
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomechanics
ISSN
0021-9290
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
13
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
2137-2144
Kód UT WoS článku
000324969500005
EID výsledku v databázi Scopus
—