Adaptive threshold and principal component analysis for features extraction of electrocardiogram signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F14%3A00219399" target="_blank" >RIV/68407700:21220/14:00219399 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/IS3C.2014.324" target="_blank" >https://doi.org/10.1109/IS3C.2014.324</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IS3C.2014.324" target="_blank" >10.1109/IS3C.2014.324</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Adaptive threshold and principal component analysis for features extraction of electrocardiogram signals
Popis výsledku v původním jazyce
This paper presents a novel approach for QRS complex detection and extraction of electrocardiogram signals for different types of arrhythmias. Firstly, the ECG signal is filtered by a band pass filter, and then it is differentiated. After that, the Hilbert transform and the adaptive threshold technique are applied for QRS detection. Finally, the Principal Component Analysis is implemented to extract features from the ECG signal. Nineteen different records from the MIT-BIH arrhythmia database have been used to test the proposed method. A 96.28% of sensitivity and a 99.71% of positive predictivity are reported in this testing for QRS complexity detection, being a positive result in comparison with recent researches.
Název v anglickém jazyce
Adaptive threshold and principal component analysis for features extraction of electrocardiogram signals
Popis výsledku anglicky
This paper presents a novel approach for QRS complex detection and extraction of electrocardiogram signals for different types of arrhythmias. Firstly, the ECG signal is filtered by a band pass filter, and then it is differentiated. After that, the Hilbert transform and the adaptive threshold technique are applied for QRS detection. Finally, the Principal Component Analysis is implemented to extract features from the ECG signal. Nineteen different records from the MIT-BIH arrhythmia database have been used to test the proposed method. A 96.28% of sensitivity and a 99.71% of positive predictivity are reported in this testing for QRS complexity detection, being a positive result in comparison with recent researches.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Adaptive threshold and principal component analysis for features extraction of electrocardiogram signals
ISBN
978-1-4799-5277-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1253-1258
Název nakladatele
IEEE Computer Society Washington
Místo vydání
Washington, DC
Místo konání akce
Taichung
Datum konání akce
10. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000366660900312