Integrated design of system structure and delayed resonator towards efficient non-collocated vibration absorption
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F25%3A00383583" target="_blank" >RIV/68407700:21220/25:00383583 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.jsv.2025.119101" target="_blank" >https://doi.org/10.1016/j.jsv.2025.119101</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jsv.2025.119101" target="_blank" >10.1016/j.jsv.2025.119101</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Integrated design of system structure and delayed resonator towards efficient non-collocated vibration absorption
Popis výsledku v původním jazyce
The problem of non-collocated vibration absorption by a delayed resonator is addressed with emphasis on system fatigue resistance and energy efficiency of control actions. The analysis is performed for a system consisting of an arbitrary large series of flexibly linked single-degree-of-freedom masses. For the stage where the vibration of the target mass is fully absorbed by the non-collocated resonator, key forces, motion amplitudes and potential energies across the system structure are assessed. Next, a complete parameter set of the resonator gain and delay is derived, and the actuation force and power needed by the resonator for the full vibration absorption is determined. The derived quantities are utilized in forming an optimization problem to balance minimal risk of fatigue across the system structure and power needed by the resonator, under the closed loop stability and parameter constraints. Next to the gain and delay of the resonator, selected structural parameters of the system are used as variables in the constrained nonlinear optimization problem. Experimental and numerical case studies are included to demonstrate benefits of the proposed integrated structural and control design.
Název v anglickém jazyce
Integrated design of system structure and delayed resonator towards efficient non-collocated vibration absorption
Popis výsledku anglicky
The problem of non-collocated vibration absorption by a delayed resonator is addressed with emphasis on system fatigue resistance and energy efficiency of control actions. The analysis is performed for a system consisting of an arbitrary large series of flexibly linked single-degree-of-freedom masses. For the stage where the vibration of the target mass is fully absorbed by the non-collocated resonator, key forces, motion amplitudes and potential energies across the system structure are assessed. Next, a complete parameter set of the resonator gain and delay is derived, and the actuation force and power needed by the resonator for the full vibration absorption is determined. The derived quantities are utilized in forming an optimization problem to balance minimal risk of fatigue across the system structure and power needed by the resonator, under the closed loop stability and parameter constraints. Next to the gain and delay of the resonator, selected structural parameters of the system are used as variables in the constrained nonlinear optimization problem. Experimental and numerical case studies are included to demonstrate benefits of the proposed integrated structural and control design.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Sound and Vibration
ISSN
0022-460X
e-ISSN
1095-8568
Svazek periodika
612
Číslo periodika v rámci svazku
119101
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
21
Strana od-do
—
Kód UT WoS článku
001494448300001
EID výsledku v databázi Scopus
2-s2.0-105004202629