Automatic Localization of Curvilinear Object in 3D Ultrasound Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F05%3A00109891" target="_blank" >RIV/68407700:21230/05:00109891 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic Localization of Curvilinear Object in 3D Ultrasound Images
Popis výsledku v původním jazyce
Utilization of tools during surgical interventions sets the problem of their accurate localization within biological tissue. The ultrasound imaging represents an inexpensive and a flexible approach for a real-time image acquisition of tissue structure with metal instruments. There are several difficulties involving processing of ultrasound images: Their noisy nature makes the localization task difficult; the objects appear irregular and incomplete. Our task is to determine the position of a curvilinearelectrode in biological tissue from a three-dimensional ultrasound image. Initially, the data are segmented by thresholding and processed with the randomized version of the RANSAC (R-RANSAC) algorithm. The curvilinear electrode is modeled by a three-dimensional cubic curve. Its shape is subject to check using a curvature measure in the hypothesis evaluation step of the R-RANSAC algorithm. Subsequently, we perform the least squares curve fitting to the data that have been marked by the R-
Název v anglickém jazyce
Automatic Localization of Curvilinear Object in 3D Ultrasound Images
Popis výsledku anglicky
Utilization of tools during surgical interventions sets the problem of their accurate localization within biological tissue. The ultrasound imaging represents an inexpensive and a flexible approach for a real-time image acquisition of tissue structure with metal instruments. There are several difficulties involving processing of ultrasound images: Their noisy nature makes the localization task difficult; the objects appear irregular and incomplete. Our task is to determine the position of a curvilinearelectrode in biological tissue from a three-dimensional ultrasound image. Initially, the data are segmented by thresholding and processed with the randomized version of the RANSAC (R-RANSAC) algorithm. The curvilinear electrode is modeled by a three-dimensional cubic curve. Its shape is subject to check using a curvature measure in the hypothesis evaluation step of the R-RANSAC algorithm. Subsequently, we perform the least squares curve fitting to the data that have been marked by the R-
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1ET101050403" target="_blank" >1ET101050403: Metody umělé inteligence v diagnostice z medicínských obrazů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Medical Imaging 2005: Ultrasonic Imaging and Signal Processing
ISBN
—
ISSN
1605-7422
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Washington
Místo konání akce
San Diego, Callifornia
Datum konání akce
12. 2. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—