This paper describes a method for determination of dielectric constant of a biological tissue. For the dielectric measurement which should be nondestructive and noninvasive for the biological substance and broadband at frequency range of network analyzeris convenient a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of network analyzer from 20 MHz to 2 GHz is under investigation and also a calibration technique and the behaviour of discrete elements in an equivalent circuit of an open ended coaxial line. Information about magnitude and phase of reflection coefficient on interface between a biological tissue and measurement probe is modeled by aid of electromagnetic field simulator. The numerical modeling is compared with real measurements. Comparison is presented as well.
Název v anglickém jazyce
The Evaluation of Reflection Method on an Open Ended Coaxial Line and its use in Dielectric Measurement
Popis výsledku anglicky
This paper describes a method for determination of dielectric constant of a biological tissue. For the dielectric measurement which should be nondestructive and noninvasive for the biological substance and broadband at frequency range of network analyzeris convenient a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of network analyzer from 20 MHz to 2 GHz is under investigation and also a calibration technique and the behaviour of discrete elements in an equivalent circuit of an open ended coaxial line. Information about magnitude and phase of reflection coefficient on interface between a biological tissue and measurement probe is modeled by aid of electromagnetic field simulator. The numerical modeling is compared with real measurements. Comparison is presented as well.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Engineering Design AED 2006
ISBN
80-86059-44-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
11. 6. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—