Vyhodnocení odrazné metody na otevřeném konci koaxiálního kabelu a její využití pro dielektrická meření
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F06%3A03129909" target="_blank" >RIV/68407700:21230/06:03129909 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation f a Reflection Method on an Open-Ended Coaxial Line and its Use in Dielectric Measurements
Popis výsledku v původním jazyce
This paper describes a method for determining the dielectric constant of a biological tissue. A suitable way to make a dielectric measurement that is nondestructive and noninvasive for the biological substance and broadband at the frequency range of thenetwork analyzer is to use a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of the network analyzer from 17 MHz to 2 GHz is under investigation and also a calibration technique and the behavior of discrete elements in an equivalent circuit of an open ended coaxial line. Information about the magnitude and phase of the reflection coefficient on the interface between a biological tissue sample and a measurement probe is modeled with the aid of an electromagnetic field simulator. The numerical modeling is compared with real measurements, and a comparison is presented.
Název v anglickém jazyce
Evaluation f a Reflection Method on an Open-Ended Coaxial Line and its Use in Dielectric Measurements
Popis výsledku anglicky
This paper describes a method for determining the dielectric constant of a biological tissue. A suitable way to make a dielectric measurement that is nondestructive and noninvasive for the biological substance and broadband at the frequency range of thenetwork analyzer is to use a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of the network analyzer from 17 MHz to 2 GHz is under investigation and also a calibration technique and the behavior of discrete elements in an equivalent circuit of an open ended coaxial line. Information about the magnitude and phase of the reflection coefficient on the interface between a biological tissue sample and a measurement probe is modeled with the aid of an electromagnetic field simulator. The numerical modeling is compared with real measurements, and a comparison is presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
50-54
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—