This paper describes a method for determining the dielectric constant of a biological tissue. A suitable way to make a dielectric measurement that is nondestructive and noninvasive for the biological substance and broadband at the frequency range of thenetwork analyzer is to use a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of the network analyzer from 300 kHz to 3 GHz is under investigation and also a calibration technique and the behavior of discrete elements in an equivalent circuit of an open ended coaxial line. Information about the magnitude and phase of the reflection coefficient on the interface between a biological tissue sample and a measurement probe is modeled with the aid of an electromagnetic field simulator. The numerical modeling is compared with real measurements, and a comparison is presented.
Název v anglickém jazyce
Workstation for Medical Diagnostics Based on Dielectric Properties Measurement of Biological Tissue
Popis výsledku anglicky
This paper describes a method for determining the dielectric constant of a biological tissue. A suitable way to make a dielectric measurement that is nondestructive and noninvasive for the biological substance and broadband at the frequency range of thenetwork analyzer is to use a reflection method on an open ended coaxial line. A coaxial probe in the frequency range of the network analyzer from 300 kHz to 3 GHz is under investigation and also a calibration technique and the behavior of discrete elements in an equivalent circuit of an open ended coaxial line. Information about the magnitude and phase of the reflection coefficient on the interface between a biological tissue sample and a measurement probe is modeled with the aid of an electromagnetic field simulator. The numerical modeling is compared with real measurements, and a comparison is presented.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Workshop 2007
ISBN
978-80-01-03667-9
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
478-479
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
19. 2. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—