Evaluation and Correction of Cable Phase Stability in High Frequency Near-Field Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A00142323" target="_blank" >RIV/68407700:21230/08:00142323 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation and Correction of Cable Phase Stability in High Frequency Near-Field Measurement
Popis výsledku v původním jazyce
In case of the near-field measurement, the radiated field by the measured antenna is received by two-dimensional scanner in defined points. During the process of the field scanning, the cable between the VNA and the scanner antenna is moved and its parameters are changed. This paper deals with the evaluation of the cable parameters changes. The dominant change is represented by the phase deviation of the cable transmission coefficient.The paper also proposes the method of the cable errors correction andevaluation of the correction method efficiency. The correction can be based on the full calibration at the reference plane of the scanner antenna feeding in all points of scanned field. The aforementioned approach is more time consuming than the proposed method, where the full calibration is performed in one selected point, while the correction of the cable parameters is based on the estimation based on the input impedance of the cable loaded by the scanner antenna.
Název v anglickém jazyce
Evaluation and Correction of Cable Phase Stability in High Frequency Near-Field Measurement
Popis výsledku anglicky
In case of the near-field measurement, the radiated field by the measured antenna is received by two-dimensional scanner in defined points. During the process of the field scanning, the cable between the VNA and the scanner antenna is moved and its parameters are changed. This paper deals with the evaluation of the cable parameters changes. The dominant change is represented by the phase deviation of the cable transmission coefficient.The paper also proposes the method of the cable errors correction andevaluation of the correction method efficiency. The correction can be based on the full calibration at the reference plane of the scanner antenna feeding in all points of scanned field. The aforementioned approach is more time consuming than the proposed method, where the full calibration is performed in one selected point, while the correction of the cable parameters is based on the estimation based on the input impedance of the cable loaded by the scanner antenna.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th Conference on Microwave Techniques COMITE 2008
ISBN
978-1-4244-2137-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Československá sekce IEEE
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
23. 4. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—