Easy Estimation of Spectral Purity of Test Signals for ADC Testing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A00146103" target="_blank" >RIV/68407700:21230/08:00146103 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Easy Estimation of Spectral Purity of Test Signals for ADC Testing
Popis výsledku v původním jazyce
ADC testing frequently confronts the problem of spectral purity of harmonic test signal. The majority of dynamic ADC test methods require test signal distortion at least 10 dB less than that of the tested ADC - the condition that cannot be practically fulfilled for testing up-to-date ADCs. More sophisticated approach to ADC testing applies the correction for test signal imperfections. In both cases test signal distortion has to be known - roughly in the first case and quite accurately in the second case. In this paper an easy method for the testing of signal spectral purity is proposed. Test signal passed by one of two simple analog filters is measured by a common ADC, whose nonlinearity is mathematically post-corrected. The results are compared with common approach applying notch filter and uncertainty analysis is performed.
Název v anglickém jazyce
Easy Estimation of Spectral Purity of Test Signals for ADC Testing
Popis výsledku anglicky
ADC testing frequently confronts the problem of spectral purity of harmonic test signal. The majority of dynamic ADC test methods require test signal distortion at least 10 dB less than that of the tested ADC - the condition that cannot be practically fulfilled for testing up-to-date ADCs. More sophisticated approach to ADC testing applies the correction for test signal imperfections. In both cases test signal distortion has to be known - roughly in the first case and quite accurately in the second case. In this paper an easy method for the testing of signal spectral purity is proposed. Test signal passed by one of two simple analog filters is measured by a common ADC, whose nonlinearity is mathematically post-corrected. The results are compared with common approach applying notch filter and uncertainty analysis is performed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
13th Workshop on ADC Modelling and Testing
ISBN
978-88-903149-3-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
University of Florence
Místo vydání
Florence
Místo konání akce
Florence
Datum konání akce
22. 9. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—