Heart Rate Detection from Ballistocardiogram
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00194663" target="_blank" >RIV/68407700:21230/12:00194663 - isvavai.cz</a>
Výsledek na webu
<a href="http://radio.feld.cvut.cz/conf/poster2012/" target="_blank" >http://radio.feld.cvut.cz/conf/poster2012/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heart Rate Detection from Ballistocardiogram
Popis výsledku v původním jazyce
The heart rate detection from the ballistocardiography signal is described in this article. Caused by the sudden ejection of blood into the great vessels with each heart beat, the body motions are in turn causing movements in a suspended supporting structure equipped with piezoelectric sensors. Three heart rate detection methods were proposed and tested on BCG signal. Similarity of processed signal allowed us to use methods based on heart rate detection from ECG signal. Proposed methods were tested on the BCG measurements from several persons. According to the results the optimal methods for the heart rate detection are the algorithms based on the autocorrelation and on the thresholding of the signal energy. Due to their simplicity, proposed algorithmsare suitable for the real-time BCG signal processing and heart rate calculation.
Název v anglickém jazyce
Heart Rate Detection from Ballistocardiogram
Popis výsledku anglicky
The heart rate detection from the ballistocardiography signal is described in this article. Caused by the sudden ejection of blood into the great vessels with each heart beat, the body motions are in turn causing movements in a suspended supporting structure equipped with piezoelectric sensors. Three heart rate detection methods were proposed and tested on BCG signal. Similarity of processed signal allowed us to use methods based on heart rate detection from ECG signal. Proposed methods were tested on the BCG measurements from several persons. According to the results the optimal methods for the heart rate detection are the algorithms based on the autocorrelation and on the thresholding of the signal energy. Due to their simplicity, proposed algorithmsare suitable for the real-time BCG signal processing and heart rate calculation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
POSTER 2012 - 16th International Student Conference on Electrical Engineering
ISBN
978-80-01-05043-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
17. 5. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—