Real-Time Robust Heart Rate Estimation Based on Bayesian Framework and Grid Filters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00197529" target="_blank" >RIV/68407700:21230/12:00197529 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-Time Robust Heart Rate Estimation Based on Bayesian Framework and Grid Filters
Popis výsledku v původním jazyce
In this chapter we discuss derivation, implementation and testing of a robust real-time algorithm for the estimation of heart rate (HR) from electrocardiograms recorded on subjects performing vigorous physical activity. We formulate the problem of HR estimation as a problem of inference in a Bayesian network, which utilizes prior information about the probability distribution of HR changes. From this formulation we derive an inference procedure, which can be implemented as a grid filter. The resulting algorithm can then follow even a rapidly changing HR, whilst withstanding a series of missed or false QRS detections. Also, the HR estimate is complete with confidence intervals to allow the identification of the moments, where the precision of HR estimation is lowered. Additionally, the computational complexity of this algorithm is acceptable for battery powered portable devices.
Název v anglickém jazyce
Real-Time Robust Heart Rate Estimation Based on Bayesian Framework and Grid Filters
Popis výsledku anglicky
In this chapter we discuss derivation, implementation and testing of a robust real-time algorithm for the estimation of heart rate (HR) from electrocardiograms recorded on subjects performing vigorous physical activity. We formulate the problem of HR estimation as a problem of inference in a Bayesian network, which utilizes prior information about the probability distribution of HR changes. From this formulation we derive an inference procedure, which can be implemented as a grid filter. The resulting algorithm can then follow even a rapidly changing HR, whilst withstanding a series of missed or false QRS detections. Also, the HR estimate is complete with confidence intervals to allow the identification of the moments, where the precision of HR estimation is lowered. Additionally, the computational complexity of this algorithm is acceptable for battery powered portable devices.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
BD - Teorie informace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GPP102%2F11%2FP109" target="_blank" >GPP102/11/P109: Techniky prostorové filtrace pro elektroencefalografické záznamy s vysokou hustotou elektrod</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Medical Applications of Intelligent Data Analysis
ISBN
978-1-4666-1803-9
Počet stran výsledku
24
Strana od-do
67-90
Počet stran knihy
348
Název nakladatele
IGI Global
Místo vydání
Hershey, Pennsylvania