Evaluation of Wearable Consumer Heart Rate Monitors Based on Photopletysmography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00220640" target="_blank" >RIV/68407700:21230/14:00220640 - isvavai.cz</a>
Výsledek na webu
<a href="http://emb.citengine.com/event/embc-2014/paper-details?pdID=1353" target="_blank" >http://emb.citengine.com/event/embc-2014/paper-details?pdID=1353</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Wearable Consumer Heart Rate Monitors Based on Photopletysmography
Popis výsledku v původním jazyce
Wearable monitoring of heart rate (HR) during physical activity and exercising allows real time control of exercise intensity and training effect. Recently, technologies based on pulse plethysmography (PPG) have become available for personal health management for consumers. However, the accuracy of these monitors is poorly known which limits their application. In this study, we evaluated accuracy of two PPG based (wrist i.e. Mio Alpha vs forearm i.e. Schosche Rhythm) commercially available HR monitors during exercise. 21 healthy volunteers (15 male and 6 female) completed an exercise protocol which included sitting, lying, walking, running, cycling, and some daily activities involving hand movements. HR estimation was compared against values from the reference electrocardiogram (ECG) signal. The heart rate estimation reliability scores for <5% accuracy against reference were following: mio Alpha 77,83% and Scosche Rhytm 76,29%. The estimated results indicate that performance of devices
Název v anglickém jazyce
Evaluation of Wearable Consumer Heart Rate Monitors Based on Photopletysmography
Popis výsledku anglicky
Wearable monitoring of heart rate (HR) during physical activity and exercising allows real time control of exercise intensity and training effect. Recently, technologies based on pulse plethysmography (PPG) have become available for personal health management for consumers. However, the accuracy of these monitors is poorly known which limits their application. In this study, we evaluated accuracy of two PPG based (wrist i.e. Mio Alpha vs forearm i.e. Schosche Rhythm) commercially available HR monitors during exercise. 21 healthy volunteers (15 male and 6 female) completed an exercise protocol which included sitting, lying, walking, running, cycling, and some daily activities involving hand movements. HR estimation was compared against values from the reference electrocardiogram (ECG) signal. The heart rate estimation reliability scores for <5% accuracy against reference were following: mio Alpha 77,83% and Scosche Rhytm 76,29%. The estimated results indicate that performance of devices
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
ISBN
978-1-4244-7929-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
3670-3673
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Chicago
Datum konání akce
26. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—