The contribution investigates the impact of frequency feature optimization on discriminating between movement-related EEG realisations associated with right shoulder elevation and right index finger flexion movements. Exhaustive search of subbands in therange from 5 to 45 Hz is performed. A classifier based on Hidden Markov Models is utilised. The results show a large variability of optimal settings among subjects and electrodes. Using subband optimization an average 3.5 % increase in classification accuracy of EEG filtered using 8-neighbor Laplacian filter was achieved, reaching an overall score of 81.2 +- 1.2 %, individual improvements ranging from 1.2 to 9.9 %. The best general setting common for all subject was confirmed as 5-40 Hz.
Název v anglickém jazyce
Subband Optimization for EEG-based Classification of Movements of the Same Limb
Popis výsledku anglicky
The contribution investigates the impact of frequency feature optimization on discriminating between movement-related EEG realisations associated with right shoulder elevation and right index finger flexion movements. Exhaustive search of subbands in therange from 5 to 45 Hz is performed. A classifier based on Hidden Markov Models is utilised. The results show a large variability of optimal settings among subjects and electrodes. Using subband optimization an average 3.5 % increase in classification accuracy of EEG filtered using 8-neighbor Laplacian filter was achieved, reaching an overall score of 81.2 +- 1.2 %, individual improvements ranging from 1.2 to 9.9 %. The best general setting common for all subject was confirmed as 5-40 Hz.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
19th International Conference on Applied Electronics 2014
ISBN
978-80-261-0276-2
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
71-74
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Pilsen
Datum konání akce
9. 10. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—