Power System Probability Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00224456" target="_blank" >RIV/68407700:21230/14:00224456 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Power System Probability Analysis
Popis výsledku v původním jazyce
System. Calculations are based on Monte Carlo and Newton-Raphson Methods. Newton-Raphson Method is used for finding single Power Flow Solution and Monte Carlo Method is used for finding Probability Power Flow Solution. The program is extension of alreadycreated program SimPoruchy 1.0 done for research into Smart Grid Power System protection. The program allowing for a quick and well-arranged output of short circuit conditions in each node of Power Grid. The program also allows for simulation of basic power grid protections elements like overcurrent, differential, and direction overcurrent protection elements. Program SimPoruchy 2.0 allows for setting the reactive and active powers in PQ and PU nodes in the form of probability density function. Programoutputs are probability density functions of currents in longitudinal sections. The program also allows for some basic conditional probabilities like maximum power of two nodes, maximum power of one node, minimum power of two nodes, and
Název v anglickém jazyce
Power System Probability Analysis
Popis výsledku anglicky
System. Calculations are based on Monte Carlo and Newton-Raphson Methods. Newton-Raphson Method is used for finding single Power Flow Solution and Monte Carlo Method is used for finding Probability Power Flow Solution. The program is extension of alreadycreated program SimPoruchy 1.0 done for research into Smart Grid Power System protection. The program allowing for a quick and well-arranged output of short circuit conditions in each node of Power Grid. The program also allows for simulation of basic power grid protections elements like overcurrent, differential, and direction overcurrent protection elements. Program SimPoruchy 2.0 allows for setting the reactive and active powers in PQ and PU nodes in the form of probability density function. Programoutputs are probability density functions of currents in longitudinal sections. The program also allows for some basic conditional probabilities like maximum power of two nodes, maximum power of one node, minimum power of two nodes, and
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
POSTER 2014 - 18th International Student Conference on Electrical Engineering
ISBN
978-80-01-05499-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
15. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—